The past 20 years have witnessed unprecedented progress in braincomputer interfaces (BCIs). However, low communication rates remain key obstacles to BCI-based communication in humans. This study presents an electroencephalogram-based BCI speller that can achieve information transfer rates (ITRs) up to 5.32 bits per second, the highest ITRs reported in BCI spellers using either noninvasive or invasive methods. Based on extremely high consistency of frequency and phase observed between visual flickering signals and the elicited single-trial steady-state visual evoked potentials, this study developed a synchronous modulation and demodulation paradigm to implement the speller. Specifically, this study proposed a new joint frequency-phase modulation method to tag 40 characters with 0.5-s-long flickering signals and developed a user-specific target identification algorithm using individual calibration data. The speller achieved high ITRs in online spelling tasks. This study demonstrates that BCIs can provide a truly naturalistic high-speed communication channel using noninvasively recorded brain activities.brain-computer interface | electroencephalogram | steady-state visual evoked potentials | joint frequency-phase modulation B rain-computer interfaces (BCIs), which can provide a new communication channel to humans, have received increasing attention in recent years (1, 2). Among various applications, BCI spellers (3-9) are especially valuable because they can help patients with severe motor disabilities (e.g., amyotrophic lateral sclerosis, stroke, and spinal cord injury) communicate with other people. Currently, electroencephalogram (EEG) is the most popular method of implementing BCI spellers due to its noninvasiveness, simple operation, and relatively low cost. However, low signal-to-noise ratio (SNR) of the scalp-recorded EEG signals and lack of computationally efficient solutions in EEG modeling limit the information transfer rates (ITRs) of EEGbased BCI spellers to ∼1.0 bits per second (bps) (1, 4). For example, the well-known P300 speller proposed by Farwell and Donchin (5) can spell up to five letters per minute (∼0.5 bps). Until recently few studies using visual evoked potentials (VEPs) demonstrated higher ITRs of 1.7-2.4 bps (6, 7). In contrast, the invasive BCI spellers in humans and monkeys show higher performance. For example, the P300 speller with electrocorticogram recordings obtained a peak ITR of 1.9 bps in a human subject (8). A recent monkey study on keyboard neural prosthesis using multineuron recordings reported an ITR up to 3.5 bps (9). Although communication speed of the EEG-based spellers has been significantly improved in the past decade (4), it still remains a key obstacle to real-life applications in humans.Recently, the BCI speller using steady-state VEPs (SSVEPs) has attracted increasing attention due to its high communication rate and little user training (4, 10, 11). An SSVEP speller typically uses SSVEPs to detect the user's gaze direction to a target character (10). Although the SSVE...
The high-speed SSVEP-based BCIs using the TRCA method have great potential for various applications in communication and control.
By incorporating the fundamental and harmonic SSVEP components in target identification, the proposed FBCCA method significantly improves the performance of the SSVEP-based BCI, and thereby facilitates its practical applications such as high-speed spelling.
Goal We present and evaluate a wearable high-density dry electrode EEG system and an open-source software framework for online neuroimaging and state classification. Methods The system integrates a 64-channel dry EEG form-factor with wireless data streaming for online analysis. A real-time software framework is applied, including adaptive artifact rejection, cortical source localization, multivariate effective connectivity inference, data visualization, and cognitive state classification from connectivity features using a constrained logistic regression approach (ProxConn). We evaluate the system identification methods on simulated 64-channel EEG data. Then we evaluate system performance, using ProxConn and a benchmark ERP method, in classifying response errors in 9 subjects using the dry EEG system. Results Simulations yielded high accuracy (AUC=0.97±0.021) for real-time cortical connectivity estimation. Response error classification using cortical effective connectivity (sdDTF) was significantly above chance with similar performance (AUC) for cLORETA (0.74±0.09) and LCMV (0.72±0.08) source localization. Cortical ERP-based classification was equivalent to ProxConn for cLORETA (0.74±0.16) but significantly better for LCMV (0.82±0.12). Conclusion We demonstrated the feasibility for real-time cortical connectivity analysis and cognitive state classification from high-density wearable dry EEG. Significance This paper is the first validated application of these methods to 64-channel dry EEG. The work addresses a need for robust real-time measurement and interpretation of complex brain activity in the dynamic environment of the wearable setting. Such advances can have broad impact in research, medicine, and brain-computer interfaces. The pipelines are made freely available in the open-source SIFT and BCILAB toolboxes.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.