Background and Aims:Ultrasonography has emerged as a novel, portable, non-invasive tool encouraging airway assessment and procedural interventions. This study assesses the feasibility of ultrasound for block of internal branch of superior laryngeal nerve (ibSLN) block during upper airway anaesthesia to aid awake fibre-optic intubation.Methods:Forty American Society of Anesthesiologists’ physical status I–II patients, aged 18–60 years, deemed to have a difficult airway (modified Mallampati class III–IV or inter-incisor distance <2.5 cm) and planned for awake fibre-optic intubation were randomised to either landmark group (L, n = 20) or ultrasound group (U, n = 20). All patients received nebulised 4% lignocaine (3 mL) and transtracheal injection 3 mL 2% lignocaine. Group L received landmark-guided bilateral ibSLN block with 1 mL 2% lignocaine. Group U received bilateral ibSLN block with 1 mL 2% lignocaine using a high-frequency ultrasound transducer to define the SLN space. The primary objective was assessment of quality of airway anaesthesia. Secondary objectives were time for intubation, haemodynamic parameters and patient perception of discomfort during procedure.Results:The quality of anaesthesia was significantly better in Group U than in Group L (P < 0.001). The mean time for intubation was shorter in Group U (71.05 ± 9.57 s) compared to Group L (109.05 ± 30.09 s, P < 0.001). Heart rate, mean arterial pressure and patient perception of discomfort were significantly increased in Group L.Conclusion:Ultrasound for ibSLN block as a part of preparation for awake fibre-optic intubation improves quality of airway anaesthesia and patient tolerance.
Background and Aims:Ultrasound (US)-guided regional blocks are becoming increasingly popular as its use increases success rate, shortens block onset time and reduces complications. Currently, there exist two methods to perform US-guided axillary brachial plexus block (US-ABPB), the perivascular (PV) and the perineural (PN) techniques. We compared the two techniques to study the block characteristics and other variables using levobupivacaine.Methods:In this prospective, randomised trial, 60 patients were randomly allocated to receive a PV (n = 30) or PN (n = 30) US-ABPB. The local anaesthetic agent, 0.5% levobupivacaine and total volume of 36 ml of solution were identical in all the subjects. For both the groups, the musculocutaneous nerve was first located and then anaesthetised with 6 ml. Subsequently in the PV group, 30 ml was deposited dorsal to the axillary artery (6 o’clock position). In PN group, the median, ulnar and radial nerves were individually anaesthetised with volumes of 10 ml each. The onset and duration of sensory block, the onset and duration of motor block, number of failed blocks and complications were noted.Results:No difference was observed between the two groups in terms of success rate (PV - 93.33%, PN - 96.66%), sensory onset (PN: 8.07 (standard deviation [SD] ± 0.651) min and PV: 8.14 [SD ± 1.079] min; P = 0.754), motor onset (PN: 14.62 [SD ± 2.077] min and PV: 14.93 [SD ± 1.844] min; P = 0.557) and total duration of anaesthesia. No complications were observed in both groups.Conclusion:The PV technique provides a simple alternative for PN US-ABPB. In the light of emerging needling positions for PV and PN techniques, this study calls for large scale trials and much research in this area before one defines best or safe approach. PV technique may be considered as an alternative method for US-ABPB in patients with anatomical variation or difficulties in identifying the individual nerves.
Background and Aims:The study aimed at comparing the performance of the novel optical Airtraq™ laryngoscope with the McCoy™ and conventional Macintosh laryngoscopes for ease of endotracheal intubation in patients with neck immobilisation using manual inline axial cervical spine stabilisation (MIAS) technique.Methods:Ninety consenting American Society of Anaesthesiologist's physical status I–II patients, aged 18–60 years, scheduled for various surgeries requiring tracheal intubation were randomly assigned into three groups of thirty each to undergo intubation with Macintosh, Airtraq™, or McCoy™ laryngoscope with neck immobilisation by MIAS technique. The ease of intubation based on Intubation difficulty scale (IDS) score, Cormack-Lehane grade of glottic view, optimisation manoeuvres and impact on haemodynamic parameters were recorded. Statistical analysis was performed with ANOVA and Bonferroni correction for post hoc tests.Results:All patients in three groups had a comparable demographic profile and were successfully intubated. The Airtraq™ laryngoscope significantly reduced the IDS (mean − 0.43 ± 0.81) as compared with both McCoy™ (mean − 1.63 ± 1.49, P = 0.001) and Macintosh laryngoscope (mean −2.23 ± 1.92, P < 0.001) and improved the Cormack-Lehane glottic view (77% grade 1 view and no patients with grade 3 or 4 view). There were less haemodynamic variations during laryngoscopy with the Airtraq™ compared to the Macintosh laryngoscope, but there was not between the Airtraq™ and McCoy™ laryngoscope groups.Conclusion:In patients undergoing endotracheal intubation with cervical immobilisation, Airtraq™ laryngoscope was superior to the McCoy™ and Macintosh laryngoscopes, with greater ease of intubation and lower impact on haemodynamic variables.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.