No data exist concerning the appication of a new robotic system with 3 mm instruments (Senhance®, Transenterix) in infants and small children. Therefore, the aim of this study was to test the system for its feasibility, performance and safety of robotic pediatric abdominal and thoracic surgery in piglets simulating infants with a body weight lower than 10 kg. 34 procedures (from explorative laparoscopy to thoracoscopic esophageal repair) were performed in 12 piglets with a median age of 23 (interquartile range: 12–28) days and a median body weight of 6.9 (6.1–7.3) kg. The Senhance® robotic system was used with 3 mm instruments, a 10 mm 3D 0° or 30° videoscope and advanced energy devices, the setup consisted of the master console and three separate arms. The amount, size, and position of the applied ports, their distance as well as the distance between the three operator arms of the robot, external and internal collisions, and complications of the procedures were recorded and analyzed. We were able to perform all planned surgical procedures with 3 mm robotic instruments in piglets with a median body weight of less than 7 kg. We encountered two non-robot associated complications (bleeding from the inferior caval and hepatic vein) which led to termination of the live procedures. Technical limitations were the reaction time and speed of robotic camera movement with eye tracking, the excessive bending of the 3 mm instruments and intermittent need of re-calibration of the fulcrum point. Robotic newborn and infant surgery appears technically feasible with the Senhance® system. Software adjustments for camera movement and sensitivity of the fulcrum point calibration algorithm to adjust for the increased compliance of the abdominal wall of infants, therefore reducing the bending of the instruments, need to be implemented by the manufacturer as a result of our study. To further evaluate the Senhance® system, prospective trials comparing it to open, laparoscopic and other robotic systems are needed.
Background: In morbidly obese patients undergoing laparoscopic bariatric surgery, the combination of obesityrelated comorbidities, pneumoperitoneum and extreme posture changes constitutes a high risk of perioperative hemodynamic complications. Thus, an advanced hemodynamic monitoring including continuous cardiac index (CI) assessment is desirable. While invasive catheterization may bear technical difficulties, transesophageal echocardiography is contraindicated due to the surgical procedure. Evidence on the clinical reliability of alternative semi-or non-invasive cardiac monitoring devices is limited. The aim was to compare the non-invasive vascular unloading to a semi-invasive pulse contour analysis reference technique for continuous CI measurements in bariatric surgical patients. Methods: This prospective observational study included adult patients scheduled for elective, laparoscopic bariatric surgery after obtained institutional ethics approval and written informed consent. CI measurements were performed using the vascular unloading technique (Nexfin®) and semi-invasive reference method (FloTrac™). At 10 defined measurement time points, the influence of clinically indicated body posture changes, passive leg raising, fluid bolus administration and pneumoperitoneum was evaluated pre-and intraoperatively. Correlation, Bland-Altman and concordance analyses were performed.
Background Blood transfusions are common medical procedures and every age group requires detailed insights and treatment bundles. The aim of this study was to examine the association of anaemia, co-morbidities, complications, in-hospital mortality, and transfusion according to age groups to identify patient groups who are particularly at risk when undergoing surgery. Methods Data from 21 Hospitals of the Patient Blood Management Network Registry were analysed. Patients were divided into age subgroups. The incidence of preoperative anaemia, co-morbidities, surgical disciplines, hospital length of stay, complications, in-hospital mortality rate, and transfusions were analysed by descriptive and multivariate regression analysis. Results A total of 1 117 919 patients aged 18–108 years were included. With increasing age, the number of co-morbidities and incidence of preoperative anaemia increased. Complications, hospital length of stay, and in-hospital mortality increased with age and were higher in patients with preoperative anaemia. The mean number of transfused red blood cells (RBCs) peaked, whereas the transfusion rate increased continuously. Multivariate regression analysis showed that increasing age, co-morbidities, and preoperative anaemia were independent risk factors for complications, longer hospital length of stay, in-hospital mortality, and the need for RBC transfusion. Conclusion Increasing age, co-morbidities, and preoperative anaemia are independent risk factors for complications, longer hospital length of stay, in-hospital mortality, and the need for RBC transfusion. Anaemia diagnosis and treatment should be established in all patients.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.