Viscosupplementation of the sacroiliac joint induced a significant degree of analgesia in all four patients. This treatment modality could represent an option in the management of sacroiliac joint pain and dysfunction.
Implanted electronic medical devices. or stimulators such as pacemakers and nerve stimulators have grown enormously in diversity and complexity over recent decades. The function and potential interaction of these devices with the perioperative environment is of increasing concern for anesthesiologists and surgeons. Because of the innate electromagnetic environment of the hospital (operating room, gastrointestinal procedure suite, and imaging suite), implanted device malfunction, reprogramming, or destruction may occur and cause physical harm (including nerve injury, blindness, deafness, burn, stroke, paralysis, or coma) to the patient. It is critical for the anesthesiologist and surgeon to be aware of the function and interaction of implanted devices, both with other implanted devices and procedures (such as magnetic resonance imaging and cardioversion) in the hospital environment. Because of these interactions, it is imperative that proper device function is assessed when the surgical procedure is complete. This review article will discuss these important issues for 12 different types of "little black boxes," or noncardiac implantable electronic medical devices.
Background:
Pituitary neurosurgery executed via the transsphenoidal endonasal approach is commonly performed for pituitary adenomas. Reasons for prolonged hospital stay include postoperative headache and protracted nausea with or without vomiting. Bilateral superficial trigeminal nerve blocks of the supra-orbital V1 and infra-orbital V2 (SION) nerves performed intra-operatively as a regional anesthetic adjunct to general anesthesia were hypothesized to decrease 6 hours postoperative morphine PCA (patient-controlled analgesia) use by patients.
Methods:
Forty-nine patients, following induction of general anesthesia for their transsphenoidal surgery, were prospectively randomized in a double-blinded fashion to receive additional regional anesthesia as either a block (0.5% ropivacaine with epi 1:200,000) or placebo/sham (0.9% normal saline).
The primary endpoint of the study was systemic morphine PCA opioid consumption by the two groups in the first 6-hours postoperatively. The secondary endpoints included (1) pain exposure experienced postoperatively, (2) incidence of postoperative nausea and vomiting, and (3) time to eligibility for PACU discharge.
Results:
Of the 49 patients that were enrolled, 3 patients were excluded due to protocol violations. Ultimately, there was no statistically significant difference between morphine PCA use in the 6 hours postoperatively between the block and placebo/sham groups. There was, however, a slight visual tendency in the block group for higher pain scores, morphine use p=0.046, and delayed PACU discharge. False discovery rate corrected comparisons at each time point and then revealed no statistically significant difference between the two groups. There were no differences between the two groups for secondary endpoints.
Conclusion:
It was found that a 6-hour postoperative headache after endoscopic trans-sphenoidal pituitary surgery likely has a more complicated mechanism involving more than the superficial trigeminovascular system and perhaps is neuro-modulated by other brain nuclei.
(ClinicalTrials.gov NCT04670614, Date of Registration 17/12/2020)
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.