In comparison to conventional scintigraphic imaging of HPGs, emerging hybrid (SPECT/CT, PET/CT) imaging techniques combine superior diagnostic performance with lower radiation exposure to patients.
ABSTRACT. Since the 1990s, stent graft implantation for aortic pathology has become an alternative to extensive surgical procedures in some patients. Indeed, many patients with such pathology are now treated endovascularly. Only limited data concerning the risk of a deterministic effect during aortic stent graft implantation are available. Accordingly, 179 consecutive patients treated in our institute between October 2002 and July 2008 with endovascular aortic stent grafts were included in this study. Dosimetric data (kerma area product (KAP) and cumulative dose at the interventional reference point (CD irp )) from radiograph reports were analysed for 172 patients. On a group of 19 patients, GAFCHROMIC XR type dosimetric films were also used to verify the automatic measurements. Readings from the integrated KAP meter were found to be too high and were therefore corrected -KAP to dose area product (DAP) and CD irp to entrance skin dose (ESD). Median DAP was 153 Gy cm 2 (35-700 Gy cm 2 ) and median ESD was 0.44 Gy (0.12-2.73 Gy). Recorded dosimetric quantities were found to be good predictors of the skin dose and highlighted 4 patients (2.3%) who received skin doses that might cause possible deterministic effects. Endovascular stent graft implantation is less invasive than a surgical procedure and is widely used; mid-term results are encouraging. In a small number of patients, deterministic effects can occur even in departments with well-trained staff. Operators should inform the patients of possible skin injury after receiving high doses of ionising radiation and proper support must be available should that occur.
Interventional cardiac procedures not only lead to significant effective doses for the patient but also can potentially cause deterministic effects on the patient's skin. Information about the peak (maximal) skin doses (PSD) received by patients during percutaneous transluminal coronary angioplasty procedures were collected from three cardiac catheter rooms. Cumulative dose at the interventional reference point (CD(IRP)) was collected for 161 patients and for 16 patients PSD was determined using Gafchromic dosimetry films. The comparison showed that CD(IRP) readings give a useful but conservative estimation of patient peak skin dose as it can lead to a significant overestimation. The median and third quartile values of CD(IRP) were 0.64 and 0.92 Gy, respectively. The 2 Gy threshold for deterministic effects was exceeded in nine patients. A good correlation was found between CD(IRP) and kerma area product measurements while the correlation with fluorography time was very weak.
The implementation of an X-ray Quality Assurance (QA) program is a legal requirement in Europe as stipulated in the EU Council Directive 97/43/EURATOM (MED). A review of the literature has identified that European countries are performing some level of QA testing of their dental X-ray equipment, although the type and level to which testing is performed can differ. The European SENTINEL co-ordination action proposed to collate a survey of equipment data for both conventional and digital dental X-ray installations among the SENTINEL partners. The European QA results confirm that systems can be operated below tolerance, and in some cases significantly so, while still in clinical use. This can occur despite servicing of equipment. The results have emphasised the fact that there is a requirement for the medical physics/engineering professions to become more closely involved in the management of dental radiology equipment. This also includes their involvement in the development and delivery of appropriate training courses for dentists and suppliers of dental radiology equipment.
In interventional cardiac procedures, staff operates near the patient in a non-uniformly scattered radiation field. Consequently, workers may receive, over a period, relatively high radiation doses. The measurement of individual doses to personnel becomes critical due to the use of protective devices and, as a consequence of the large number of methods proposed to assess the effective dose, great variability in monitoring programmes is expected among European countries. SENTINEL consortium has conducted a survey on staff dosimetry methods and on the level of staff exposure in 12 European cardiac centres demonstrating the urgent need to harmonise dosimetry methods. From the dosimetry survey, constraint annual effective dose of 1.4 mSv and Hp(0.07) over the protective apron of 14 mSv are proposed for the optimisation the exposure the most-exposed operator.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.