Indoor air quality refers to the air quality in and around laboratory buildings and facilities, which directly affects the health and comfort of workers. Poor air quality poses numerous health challenges to the laboratory workers and environment, and causes sick building syndrome (SBS) among workers. The objective of this study is to determine associations of SBS related to indoor air concentration in a dose-dependent manner among Nigerian laboratory university workers. This was a cross-sectional study on a population-based sample of Nigerian university laboratories and the workers. Data were collected using an indoor air quality control meter, dosimeter tubes gases of interest, and a set of questionnaires . The results showed that the mean indoor air concentrations in a dose-dependent manner for chemical parameters range from 473.0 ppm to753.0 ppm, 17.9 ppm to 27.3 ppm, 5.7 ppm to 8.5 ppm, and 6.3 ppm to 9.1 ppm for CO 2 , CO, NO 2 , H 2 S and SO 2 , respectively. The prevalence of SBS, i.e., skin-related syndrome (SRS) is 38.5%, general-related symptom (GRS) is 28.3%, mucosal-related symptom (MRS) is 19.2% and at least one score was a respiratory-related symptom (RRS), which is 13.9%.
: The chemicals from laboratories pose a significant risk forinducing erythema, an abnormal redness of the skin, as a result of poor occupational and environmental factors that promote hypersensitivity to a chemical agent. The aim of this present study was to determine the occupational and environmental risk factors influencing the inducement of erythema in laboratory workers due to exposure to chemicals. This was a cross-sectional study on a population-based sample of Nigerian university laboratory workers. Data were collected using the erythema index meter and an indoor air control meter. The study included 287 laboratory workers. The laboratory workers who properly used personal protective equipment (PPE) were 60% less likely to have induced erythema (adjusted odds ratio (AOR) = 0.40; 95% confidence interval CI: 0.22–0.77; probability value p = 0.011). The chemical mixture exceeding the permissible exposure limit (PEL) was found to have a small effect in inducing the erythema (AOR = 4.22; 95%CI: 2.88–12.11; p = 0.004). Most of the sampled laboratories where the respondents worked had unsuitable temperatures (AOR = 8.21; 95% CI: 4.03–15.01; p = 0.001). Erythema was more frequently found in the respondents who spent 4–5h in the laboratory (AOR = 3.11; 95%CI: 1.77–9.23; p = 0.001). However, high levels of ventilation reduce the likelihood of erythema in a laboratory by 82% (0.18). Multiple logistic regressions revealed that PPE, PEL, exposure time, temperature, and ventilation were the probable predictive factors associated with the inducement of erythema. Providing better educational knowledge and improving the attitude towards hazards and safety in a laboratory would lead to reduced rates of new cases.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.