Background: We assessed image quality of dedicated breast positron emission tomography (dbPET) at the detector's edge by phantom and clinical studies.Methods: A breast phantom with four spheres (16, 10, 7.5, and 5 mm diameter) was filled with 18F-fluorodeoxyglucose solution (sphere-to-background ratio, 8:1). The spheres occupied five different positions from the top edge to the centre of the detector and were scanned for 5 min in each position. Reconstructed images were visually evaluated, and % background variability (%N5mm), % contrast (%QH,5mm), and contrast-to-noise ratio (QH,5mm/N5mm) for the 5 mm sphere; and coefficient of variation of the background (CVbackground) were calculated. Subsequently, clinical cases were analysed. Tumour-to-background ratios (TBRs) between breast cancer near the chest wall (close to the detector’s edge; peripheral group) and at other locations (non-peripheral group) were compared. The TBR of each lesion was compared between dbPET and PET/computed tomography (CT).Results: Closer to the detector’s edge, the %N5mm and CVbackground increased and %QH,5mm and QH,5mm/N5mm decreased in the phantom study. The disadvantages of this placement were visually confirmed. Regarding clinical images, TBR of dbPET was significantly higher than that of PET/CT in both the peripheral (12.1±6.2 vs. 6.5±3.4, p=0.0001) and non-peripheral (13.1±7.1 vs. 7.7±7.4, p=0.0004) groups. There was no significant difference in TBR of dbPET between the peripheral and non-peripheral groups (12.1±6.2 vs. 13.1±7.1, p=0.6367).Conclusion: The phantom study revealed poorer image quality closer to the detector edge at a depth of 1/8 of the axial field of view (FOV) than at other more central parts. In clinical studies, however, lesion detectability of dbPET was the same regardless of the lesion position, and it was higher than that in PET/CT. dbPET has a great potential for detecting breast lesions near the chest wall if they are within the FOV, even in young women with small breasts.
Background: Using phantoms and clinical studies in prone hanging breast imaging, we assessed the image quality of a commercially available dedicated breast PET (dbPET) at the detector's edge, where mammary glands near the chest wall are located. These are compared to supine PET/CT breast images of the same clinical subjects.Methods: A breast phantom with four spheres (16, 10, 7.5, and 5 mm diameter) was filled with 18F-fluorodeoxyglucose solution (sphere-to-background activity concentration ratio, 8:1). The spheres occupied five different positions from the top edge to the centre of the detector and were scanned for 5 min in each position. Reconstructed images were visually evaluated, and the contrast-to-noise ratio (CNR), contrast recovery coefficient (CRC) for the 5-mm sphere, and coefficient of variation of the background (CVB) were calculated. Subsequently, clinical images obtained with standard supine PET/CT and prone dbPET were retrospectively analysed. Tumour-to-background ratios (TBRs) between breast cancer near the chest wall (close to the detector’s edge; peripheral group) and at other locations (non-peripheral group) were compared. The TBR of each lesion was compared between dbPET and PET/CT.Results: Closer to the detector’s edge, the CNR and CRC decreased while the CVB increased in the phantom study for all sphere sizes. The disadvantages of this placement were visually confirmed. Regarding clinical images, TBR of dbPET was significantly higher than that of PET/CT in both the peripheral (12.38±6.41 vs 6.73±3.5, p=0.0006) and non-peripheral (12.44±5.94 vs 7.71±7.1, p=0.0183) groups. There was no significant difference in TBR of dbPET between the peripheral and non-peripheral groups.Conclusion: The phantom study revealed poorer image quality at <2 cm distance from the detector's edge than at other more central parts. In clinical studies, however, the visibility of breast lesions with dbPET was the same regardless of the lesion position, and it was higher than that in PET/CT. dbPET has a great potential for detecting breast lesions near the chest wall if they are at least 2 cm from the edge of the FOV, even in young women with small breasts.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.