The main objectives of this publication are: 1) to attract the attention of energy specialists to the problems of reliability and electrical safety of 6-10 kV overhead electrical networks with isolated neutral, operating in conditions of single-phase insulation damage; 2) substantiation of the feasibility of introducing a fundamentally new way to improve the efficiency of 6-10 kV distribution networks, based on the resonanceless limitation of the single-phase ground fault current arising from the breakdown of the insulator and the use of its own infrastructure of the electrical network for remote identification of the place of its occurrence. The expediency of including a nonlinear surge suppressor between the traverse and the grounding outlet of the reinforced concrete support is confirmed by the positive results of experimental studies carried out on the basis of high-voltage testing laboratories of IDGC of Center PJSC - Orelenergo and EnerGarant LLC. The use of deductive analysis allowed the authors to select a reliable and affordable electrical insulating material installed between the support and the traverse, as well as to formulate the main requirements for it, including taking into account weather and climatic factors. The analysis of various methods of transmitting information about the place of occurrence of the insulator damage made it possible to establish the predominant advantage of a wired communication channel using its own 6-10 kV electric network infrastructure. The authors have developed an original circuitry solution that provides remote identification of the insulator damage location using a thyristor shunting the nonlinear surge suppressor, according to a given switching algorithm, and also provides local identification of the insulator breakdown by means of special signaling devices with volatile power supply. It is expected that the proposed method, with relatively low investment, will significantly reduce the level of accidents and electrical hazards in overhead distribution networks of 6-10 kV, as well as minimize the costs associated with their operation and undersupply of electrical energy.
The paper considers options for the implementation of the technical condition monitoring of the of power supply system elements, the assessment of overgrowing of the power line routes using an unmanned aerial vehicle. A method for emergency control of an unmanned aerial vehicle used to monitor the technical condition of 6-10 kV overhead power lines has been proposed. This method is used in case of loss of radio communication between the unmanned aerial vehicle and the ground control station. The method is based on the activation of the automatic piloting system allowing the unmanned aerial vehicle flight to continue to the pre-determined emergency landing area. The autopilot is carried out by means of a servo controller and sensitive sensors reacting to the intensity of the electromagnetic field of a 6-10 kV overhead power line.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.