The conventional incision for donor hepatectomy is a right subcostal incision with a midline extension. With increased experience in both donor hepatectomy and laparoscopy, the conventional incision can be shortened to a significant extent. Laparoscopic mobilization of the liver coupled with a hand port allows the insertion of one hand inside the abdomen for control; this makes small-incision donor hepatectomy a technically feasible alternative. We compared 26 right lobe donor hepatectomies performed with a laparoscopy-assisted technique (the laparoscopy-assisted donor hepatectomy group) to 24 donor hepatectomies performed with the conventional open technique (the conventional donor hepatectomy group). The donors in both groups and their recipients were followed for 6 months. Pain, discomfort related to the scar [including abdominal wall sensorineural deficits (numbness and differences in tactile and temperature sensations) and tightness around the scar], and donor quality of life (assessed with the International Quality of Life Assessment Short Form 8 scoring system) were compared between the 2 groups. In conclusion, laparoscopy-assisted surgery can be a technically feasible alternative in experienced hands, and as with other minimally invasive surgeries, it has advantages such as significantly less pain, reduced incision-related complications, and better donor quality of life during the early postoperative period without compromising donor safety.
Biliary complications are regarded as the Achilles' heel of liver transplantation, especially for living donor liver transplantation (LDLT) due to smaller, multiple ducts and difficult ductal anatomy. Overall biliary complications reported in most series are between 10% and 30%. This study describes our modified technique of biliary anastomosis and its effects on incidence of biliary complications. This was a single‐center retrospective study of 148 adult LDLT recipients between December 2011 and June 2014. Group 1 (n = 40) consisted of the first 40 patients for whom the standard technique of biliary anastomosis (minimal hilar dissection during donor duct division, high hilar division of the recipient bile duct, and preservation of the recipient duct periductal tissue) was used. Group 2 (n = 108) consisted of 108 patients for whom biliary anastomosis was done with the addition of corner‐sparing sutures and mucosal eversion of the recipient duct to the standard technique. Primary outcome measures included biliary complications (biliary leaks and strictures). Biliary complications occurred in 7/40 patients in group 1 (17.5%) and in 4/108 patients in group 2 (3.7%). The technical factors mentioned above are aimed at preserving the blood supply of the donor and recipient ducts and hold the key for minimizing biliary complications in adult‐to‐adult LDLT. Liver Transpl 22:14‐23, 2016. © 2015 AASLD.
Many infections are transmitted from a donor to a recipient through organ transplantations. The transmission of dengue virus from a donor to a recipient in liver transplantation is a rare entity, and currently, there is no recommendation for screening this virus prior to transplantation. We report a case of transmission of dengue virus from donor to recipient after liver transplantation. The recipient had a history of multiple admissions for hepatic encephalopathy and ascites. He was admitted in the ICU for 15 days for chronic liver disease, ascites, and acute kidney injury before transplantation. The donor was admitted 1 day before transplantation. The donor spiked fever on postoperative day 2 followed by thrombocytopenia and elevated liver enzymes. The donor blood test was positive for dengue NS1 antigen. The recipient also had a similar clinical picture on postoperative day 5 and his blood test was also positive for dengue NS1 antigen. Hence, the diagnosis for posttransplant donorderived allograft-related transmission of dengue infection was made. Both recipient and donor were treated with supportive measures and discharged after their full recovery on postoperative days 9 and 18, respectively. The effect of immunosuppression on dengue presentation is still unclear and there is lack of literature available. In our case, the recipient developed dengue fever similar to general population without showing any feature of severe graft dysfunction. We have concluded that dengue virus can also be transmitted from donor to recipient, and immunosuppression did not have any adverse effect on the evolution of dengue fever within the recipient. Delhi being a hyperendemic zone, screening for donors (especially in season time) for dengue virus seems to be the best preventive method to control donor-derived transmission of dengue to recipient. ( J CLIN EXP HEPATOL 2016;6:59-61) T he epidemiology of dengue, an endemic disease, has been changing rapidly in Delhi. Transmission of dengue virus from donor to recipient is rarely reported. Currently, there is no recommendation for screening this virus prior to transplantation. We describe a case of transmission of dengue virus from donor to recipient after liver transplantation. CASEA 40-year-old man presented with cryptogenic liver disease (since 2013). He was admitted with features suggestive of decompensated chronic liver disease with ascites (no SBP), AKI, and hepatic encephalopathy. He had history of multiple admissions in the past with a diagnosis of hepatic encephalopathy. In view of recurrent hepatic encephalopathy and decompensated chronic liver disease with child class C (13/15) MELD score of 26, the patient was advised for liver transplantation. The donor was his 29-year-old brother-in-law, who was admitted 1 day prior to transplant. He was evaluated as per protocol. After stabilization of recipient (15th day of his admission), he underwent living donor liver transplantation, which was uneventful.The donor spiked fever of 103 8F on POD 3 and continued to have fever for t...
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.