Calculations are performed to determine the parameters for the adjustment of a friction dilatometer with allowance for local contact strains caused by impact against structural elements of the instrument. An analysis of the results of the calculations is used as a basis for proposing a method of adjusting it for specific test conditions. Experimental data is presented that demonstrates the feasibility of using the instrument to measure the linear wear of high-strength contacts.Experience in the operation of different types of transportation equipment shows that the overwhelming majority of failures are attributable to mechanical systems. Approximately 85 % of these failures are in turn connected to some extent with the wear of equipment parts. The failures lead to significant material losses from the work required to restore the parts to working order during scheduled and unscheduled repairs and servicing [1, 2]. One of the most effective methods of increasing the tribological reliability (wear resistance) of these parts is to conduct objective laboratory wear tests of the materials used to make them.The accuracy of evaluations of the wear of rubbing parts can be improved significantly only by using an instrument designed especially for this purpose -the friction dilatometer [3, 4]. However, this instrument can be efficiently used only if it is properly adjusted and controlled. A simplified diagram of a friction dilatometer is shown in Fig. I.Information on the dilatation of the tribometric system is sent along a circuit that includes the following components: test specimen 8, 9; specimen holder 7; rod 5 with lateral stop 10; main rod 2; linear displacement sensor i; amplifier, recorder, computer (not shown in Fig. 1). One of the main components is the device used to adjust the measurement circuit. It consists of parts 1, 2, 11, and 12 and is installed in the instrument's housing 4. With rotation of the abradant 9, which interacts with the specimen 8, the displacements caused by wear, thermal expansion, and radial vibration of the parts of the measurement system are transmitted to the adjustment device. A change in the working gap 6 between the stop 10 and the adjustment screw 11 reduces the effect of the radial vibrations on the accuracy of evaluation of the linear wear of the tribomechanical systems that are tested.In adjusting the instrument for testing specific parts, it is necessary to optimize the force that tightens the friction clutches 3, 6, and the working gap in the adjustment device 5 for the specified test conditions.The force which tightens the clutches 3 should be such that the movement of parts 1, 2, 11, and 12 does not continue after they are acted upon by the lateral stop 10 (such movement is possible if the stop is moved downward). If we ignore the compression of bodies I0 and I 1, then the equation of motion of the adjustment device can be represented in the form m,a =/::st + m,g --Ffr ,,where m I is the mass of the adjustment device (m I = 0.1256 kg in the PCLW-01 dilatometer); a is the accel...
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.