Metal-on-metal articulations were reintroduced to reduce polyethylene particleinduced osteolysis. Elevated serum metal levels have been detected at short-and intermediateterm follow-up. There is little knowledge about long-term effects of increased ionic metal generation. Our study was undertaken to provide information about long-term survival, clinical outcome, radiographic appearance, and serum metal concentrations after a minimum 10 years follow-up with a metal-on-metal hip prosthesis: 105 cementless primary total hip prostheses with metal-on-metal articulating surfaces were implanted in 98 patients with a mean age of 56 years. Clinical data, radiographs, and blood samples were obtained at a follow-up visit 10 years after implantation. Serum cobalt and chromium levels were determined with use of atomic absorption spectrometry. General laboratory analyses included a full blood count and kidney function parameters. The Harris score was 92 points and the UCLA score 6 points after 10 years. Small osteolytic lesions and radiolucent lines were found in Gruen's zones 1, 7, 8, and 14. The probability of survival was 98.6%. The median serum cobalt concentration of the 22 patients with their hip replacement as the only source of cobalt was 0.75 mg/L (range, 0.3-50.1 mg/L). No patient was diagnosed with renal insufficiency during the study period. Five patients were diagnosed with a malignancy between surgery and the follow-up. We do not have evidence of an increased rate of primary malignancies nor could we detect renal failure in our study group. Serum metal levels did not differ from short-and intermediate term follow-up values. ß
We determined serum cobalt levels in 55 patients by atomic absorption spectrophotometry before and after implantation of uncemented total hip arthroplasties. In a randomised, prospective trial 27 wrought Co-28Cr-6Mo-0.2C metal-on-metal articulations were compared with 28 ceramic-on-polyethylene hips which did not contain cobalt. Other sources of iatrogenic cobalt loading were excluded. The metal-on-metal group produced detectable serum cobalt levels (median 1.1 microg/l after one year) which were significantly different (p < 0.0001) from those of the ceramic-on-polyethylene control group (median below detection limit of 0.3 microg/l after one year). Our findings indicate that metal-on-metal bearings generate some systemic release of cobalt.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.