High-energy radiation can cause different malfunctions on CIED, particularly ICD, even without direct exposure to ionizing radiation due to scattered radiation of neutrons produced by the linear accelerator.
Background and purpose: In radiation therapy, defining the precise borders of cancerous tissues and adjacent normal organs has a significant effect on the therapy outcome. Deformable models offer a unique and robust approach to medical image segmentation. The objective of this study was to investigate the reliability of segmenting organs-at-risk (OARs) using three well-known local region-based level-set techniques. Methods and materials: A total of 1340 non-enhanced and enhanced planning computed tomography (CT) slices of eight OARs (the bladder, rectum, kidney, clavicle, humeral head, femoral head, spinal cord, and lung) were segmented by using local region-based active contour, local Chan-Vese, and local Gaussian distribution models. Quantitative metrics, namely Hausdorff Distance (HD), Mean Absolute Distance (MAD), Dice coefficient (DC), Percentage Volume Difference (PVD) and Absolute Volumetric Difference (AVD), were adopted to measure the correspondence between detected contours and the manual references drawn by experts. Results: The results showed the feasibility of using local region-based active contour methods for defining six of the OARs (the bladder, kidney, clavicle, humeral head, spinal cord, and lung) when adequate intensity information is available. While the most accurate results were achieved for lung (DC = 0.94) and humeral head (DC = 0.92), a poor level of agreement (DC < 0.7) was obtained for both rectum and femur. Conclusion: Incorporating local statistical information in level set methods yields to satisfactory results of OARs delineation when adequate intensity information exists between the organs. However, the complexity of adjacent organs and the lack of distinct boundaries would result in a considerable segmentation error.
With a low-energy accelerator, neither malfunctions nor electromagnetic interferences were detected radiating the ICDs at doses usually reaching the ICD pocket during radiotherapy sessions. In this context, magnet application to avoid oversensing and inappropriate therapy seems, therefore, useless.
Background
Breast intraoperative electron radiation therapy (B-IOERT) can be used in clinical practice both as elective irradiation (partial breast irradiation – APBI) in low risk breast cancer patients, and as an anticipated boost. The procedure generally includes the use of a shielding disk between the residual breast and the pectoralis fascia for the protection of the tissues underneath the target volume. The aim of the study was to evaluate the role of intraoperative ultrasound (IOUS) in improving the quality of B-IOERT.
Patients and methods
B-IOERT was introduced in Trieste in 2012 and its technique was improved in 2014 with IOUS. Both, needle and IOUS were used to measure target thickness and the latter was used even to check the correct position of the shielding disk. The primary endpoint of the study was the evaluation of the effectiveness of IOUS in reducing the risk of a disk misalignment related to B-IOERT and the secondary endpoint was the analysis of acute and late toxicity, by comparing two groups of patients treated with IOERT as a boost, either measured with IOUS and needle (Group 1) or with needle alone (Group 2). Acute and late toxicity were evaluated by validated scoring systems.
Results
From the institutional patients who were treated between June 2012 and October 2019, 109 were eligible for this study (corresponding to 110 cases, as one patients underwent bilateral conservative surgery and bilateral B-IOERT). Of these, 38 were allocated to group 1 and 72 to group 2. The target thickness measured with the IOUS probe and with the needle were similar (mean difference of 0.1 mm, p = 0.38). The percentage of patients in which the shield was perfectly aligned after IOUS introduction increased from 23% to more than 70%. Moreover, patients treated after IOUS guidance had less acute toxicity (36.8% vs. 48.6%, p = 0.33) from radiation therapy, which reached no statistical significance. Late toxicity turned out to be similar regardless of the use of IOUS guidance: 39.5% vs. 37.5% (p = 0.99).
Conclusions
IOUS showed to be accurate in measuring the target depth and decrease the misalignment between collimator and disk. Furthermore there was an absolute decrease in acute toxicity, even though not statistically significant, in the group of women who underwent B-IOERT with IOUS guidance.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.