Film coatings today allow to create large number of diverse structures in electronics, microelectronics, optics, architecture and construction. Leading technologies in this area are magnetron deposition technologies. The problem of magnetron deposition methods is insufficient reproducibility of the composition and properties of coatings, caused by the instability of the parameters of a magnetron discharge in the presence of a reactive gas. There are stabilization systems that make it possible to make reproducible films, but all of them have a number of issues. The aim of the work was to develop a system for stabilizing the reactive magnetron sputtering process for film coating technologies that will eliminate the described shortcomings of existing systems.The developed system of stabilization: automatic and cumulative of sensors, actuators, microcomputer with control software, as well as devices providing interaction of sensors and actuators with a microcomputer. The sensors of the system may be vacuum gauges or pressure sensors, discharge current and voltage sensors of sprays, optical sensors for recording spectral element processes, absorption of a plasma of a magnetron discharge. The actuators of the system are gas flowers, as well as valves. Number and type of sensors and actuators from existing technologies and requirements for ongoing processes. The control software allows to flexibly adjust the system (to form control loops, then to assign sensors and actuators in accordance and to choose control algorithms, to set parameters and operating modes of control loops). Thus, the developed system is adaptable to a wide range of process plants and processes.System operability was confirmed by the process of magnetron deposition of a titanium oxide film. The deviation of the level of the sensor signals from the required values during the process did not exceed 3 %, which allows obtaining high-quality coatings.
An automated system for controlling oxygen flow in vacuum-plasma magnetron deposition of oxides with simultaneous monitoring of gas impurities in a vacuum chamber is proposed. Features of using compact spectrometers in such a system are considered. The precision of controlling the flow of metal and oxygen particles during deposition of Ti and Al oxides is determined. The sensitivity to impurity content is estimated. The effect of sputtered metal and type of coating (metal or oxide) on the sensitivity to impurities of air, water vapor, and oil in the vacuum chamber is found.Introduction. The use of optical-spectral flow controllers for gases [1][2][3] in magnetron deposition of oxides causes technical difficulties with the recording of the intensity of oxygen spectral lines using optical sensors in light filters. A narrow-band interference light filter with a transmission half-width of less than 1.5 nm and a low transmission beyond the limits of the operating range is required to identify the strongest line OI at 777.3 nm because this line lies very close to bright argon lines, the main component of the working gas. The discharge power and pressure in the vacuum chamber must be very stable for controllers with a single-channel control algorithm to operate if the optical sensor records the intensity of spectral lines of the sputtered material [4]. Compact multi-channel radiation-spectrum recorders, for example, S100 and SL40-2 models of Solar [5, 6], and spectrometers of Ocean Optics [7] have been recently produced. These are of great interest for use in optical-spectral systems for controlling gas flow. This is due to the rather high-quality specifications of the spectrometers and their rather small size. Moreover, owing to the rapid recording of the spectrum (minimal recording time is 7 msec) and the spectral resolution, which is comparable with narrow-band interference light filters, they can also be used simultaneously to monitor the chemical purity of process plasma streams. Herein we propose a system for automated control of working gas flows in vacuum-plasma magnetron processes for depositing coatings of complicated chemical composition with simultaneous monitoring of gaseous impurities in the vacuum chamber. Features of using compact S100 and SL40-2 spectrometers in such a system as a multichannel sensor are examined using deposition of titanium and aluminum oxide films as an example. The capabilities of the system for simultaneous monitoring of oxygen, water, and oil impurities in the vacuum chamber are determined.Experimental. Experiments were conducted in a vacuum apparatus for magnetron sputtering that was equipped with a gas-flow controller [3] and devices for regulated admission to the vacuum chamber of oxygen, water vapor, and oil. We used a planar DC magnetron with discharge power of 1.0-1.5 kW and a vacuum-chamber pressure of 0.3-0.4 Pa. Oxygen flow during deposition of titanium and aluminum oxide films was controlled by a single-channel algorithm by identifying atomic spectral lines of sputtered ...
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.