Fat blends, formulated by mixing a highly saturated fat (palm stearin or fully hydrogenated soybean oil) with a native vegetable oil (soybean oil) in different ratios from 10:90 to 75:25 (wt%), were subjected to chemical interesterification reactions on laboratory scale (0.2% sodium methoxide catalyst, time = 90 min, temperature = 90°C). Starting and interesterified blends were investigated for triglyceride composition, solid fat content, free fatty acid content, and trans fatty acid (TFA) levels. Obtained values were compared to those of low-and high-trans commercial food fats. The interesterified blends with 30-50% of hard stock had plasticity curves in the range of commercial shortenings and stick-type margarines, while interesterified blends with 20% hard stock were suitable for use in soft tubtype margarines. Confectionery fat basestocks could be prepared from interesterified fat blends with 40% palm stearin or 25% fully hydrogenated soybean oil. TFA levels of interesterified blends were low (0.1%) compared to 1.3-12.1% in commercial food fats. JAOCS 75, 489-493 (1998).
In the present study, neutral oil loss (distillative and mechanical carry-over) during physical refining of coconut oil was quantified. Neutral oil loss seems to depend on both the crude oil quality and the process conditions during deodorization. The distillation of volatile glyceridic components (monoand diglycerides), originally present in the crude oil, was confirmed as the major cause for the neutral oil loss. The amount of these volatile components in crude coconut oils cannot be derived as such from the initial free fatty acid content. A lower deodorization pressure with less sparge steam resulted in a larger neutral oil loss than a higher pressure with more steam. A "deodorizability" test on a laboratory scale under standardized conditions (temperature = 230°C, pressure = 3 mbar, time = 60 min, sparge steam = 1%), to evaluate crude oil quality and to obtain a more accurate prediction of the expected neutral oil loss and free fatty acid content in the fatty acid distillate, is described.
Analyse von Tocopherolen mittels Gas-Flüssigkeits-und Hochleistungsflüssigchromatographie: eine vergleichende Untersuchung. Ausgewählte Normalphasen-HPLC-und gaschromatographische Methoden wurden für die Analyse von Tocopherolen in pflanzlichen Ölen untersucht. Wiederholbarkeit, Genauigkeit und/oder Wiederfindung wurden für beide Methoden bestimmt und mit Daten der offiziellen Methodik verglichen. Die größte Genauigkeit wurde mittels der Normalphasen-HPLC-Technik, basierend auf der AOCS-Methode Ce 8-89, erzielt, was wahrscheinlich durch die kurze und einfache Probenaufbereitung erklärt werden kann. Es wurden Tocopherolgehalte von sechzehn voll raffinierten Pflanzenölen mit sowohl GLC als auch HPLC bestimmt. Die Regressionsanalyse zeigte, daß Tocopherolgehalte, die mittels GLC ermittelt worden sind, um 6,1% höher waren als die vergleichbaren HPLC-Daten. Obwohl die ermittelte Wiederfindungsrate der GLC-Methode gut ist, scheint es, daß bei der Probenaufbereitung zusätzlich eine Auftrennung mittels Dünnschichtchromatographie eingeführt werden sollte, um eine Überlappung der Peaks zwischen Tocopherolen und einigen störenden Substanzen der unverseifbaren Fraktion zu vermeiden.a Department of Food Technology and Nutrition, University of Ghent, Gent, Belgium. b De Smet Engineering N. V., Edegem, Belgium.vents and reagents used were analytical or HPLC grade and purchased from Acros Organics (Geel, Belgium). Gas liquid chromatographySample preparation: The selected GLC procedure was based on the AOCS official method Ce 3-74 [6]. 5-7 g of oil were saponified in the presence of 0.15 % butylhydroxytoluene as antioxidant [5]. Tocopherols and sterols were not separated by thin-layer chromatography prior to GLC analysis. Derivatization was accomplished by the addition of 1 ml acetic acid anhydride, keeping the mixture 10 min at 140 °C. After cooling, 1 µl was injected in the gas chromatograph.Gas-chromatographic conditions: Analyses were carried out on a Carlo Erba 4160 chromatograph equipped with a flame-ionization detector (FID) and a split injector (split ratio 1:40) (Carlo Erba, Milano, Italy). A fused silica capillary column coated with a nonpolar stationary phase (CP TM Sil 5CB, 25 m × 0.25 mm internal diameter; 0.25 µm film thickness, Chrompack, The Netherlands) was selected. The oven temperature was kept constant at 290 °C. Injector and detector were maintained at 340 °C. All tocopherol homologues eluted within 15 min. The total analysis time was set at 30 min to assure the elution of all sterols.Identification of the individual tocopherols was realized with pure standards as reference compounds.Quantification: Correction factors were determined for all tocopherols by analyzing different mixtures of the tocopherol standards and an internal standard (3-octadecyloxy-1,2-propanediol). Quantitative analyses were performed with a Shimadzu RC3A integrator. High-performance liquid chromatographyPrinciple: The selected NP-HPLC procedure was based on the previously mentioned IUPAC method 2.432 [5] and the AOCS official method Ce ...
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.