A simple, rapid, and environmentally-friendly spectrophotometric method for nitrite detection was developed. Detection was based on a redox reaction with iodide ions in an acidic condition. The reaction was evaluated by detecting the increase in absorbance of the colored product of iodine at 362 nm wavelength. To obtain a good spectrophotometric performance, the iodide ions concentration, hydrochloric acid concentration, and reaction time were optimized. In the optimal condition, the developed spectrophotometric method provided a linear range of 0.0625 to 4.00 mg L−1 (r = 0.9985), reaction time for 10 min, a limit of detection of 25 µg L−1, and a limit of quantitation of 85 µg L−1. This method showed good repeatability (RSD < 9.21%), high sample throughput (9 samples min−1), and good accuracy (recovery = 88 ± 2 to 99.5 ± 0.4%). The method has the potential to be used in crime scene investigations as a rapid screening test for gunshot residue detection via nitrite detection.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.