Thermal stability of the C2 domain for an IgG1 monoclonal antibody and its aggregation kinetics were systematically studied at pH 4.8, below its pI of 8.8 in individual solutions of arginine salts with acetate, glutamate (Glu), chloride, and sulfate as the anion, in comparison to sodium chloride and sodium sulfate. Thermal unfolding temperature, T, an indicator of thermal stability, was measured by both differential scanning calorimetry (DSC) and differential scanning fluorimetry (DSF). The aggregation kinetics was determined by assessing reversibility for the C2 domain in the DSC repetitive scans and then cross-examined by the isothermal aggregation study measured by size exclusion chromatography. The effect of Arg on the thermal stability and aggregation kinetics of the antibody is shown to be strongly anion-dependent: both ArgAceate and ArgGlu improve the stability, while both ArgSO and ArgCl decrease it. Furthermore, the addition of ArgCl and ArgSO accelerates the aggregation kinetic, but to a lesser extent than the respective Na salt, suggesting that Arg binds to the antibody more strongly than Na. However, the binding of Arg did not lead to more destabilization of the C2 domain by the Arg salts at low concentrations, comparing to the respective Na salt. This finding indicates that Arg prefers the protein surface, rather than the exposed backbone upon unfolding. Furthermore, the change in the ranking for affecting the thermal stability and aggregation kinetics as the salt concentration increases implies the presence of other multiple mechanisms, e.g., cluster formation through the homoion pairing between Arg molecules and their preferential exclusion from the protein surface, and heteroion pairing between Arg and SO.
Glass prefillable syringes are lubricated with silicone oil to ensure functionality and a consistent injection for the end user. If excessive silicone is applied, droplets could potentially result in aggregation of sensitive biopharmaceuticals or clouding of the solution. Therefore, monitoring and optimization of the applied silicone layer is critical for prefilled syringe development. The hydrophobic properties of silicone oil, the potential for assay interference, and the very small quantities applied to prefilled syringes present a challenge for the development of a suitable assay. In this work we present a rapid and simple Fourier transform infrared (FTIR) spectroscopy method for quantitation of total silicone levels applied to prefilled syringes. Level-dependent silicone oil migration occurred over time for empty prefilled syringes stored tip-up. However, migration from all prefilled syringes with between 0.25 and 0.8 mg of initial silicone oil resulted in a stable limiting minimum level of between 0.15 and 0.26 mg of silicone in the syringe reached after 1 to 4 years of empty tip-up storage. The results of the FTIR assay correlated well with non-destructive reflectometry characterization of the syringes. This assay can provide valuable data for selection of a robust initial silicone oil target and quality control of prefilled syringes intended for biopharmaceuticals.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.