Recently, translucent zirconia has become the most prevalent material used as a restorative material. This study aimed to compare the crown fracture load of the four most common different translucent zirconia brands available in the market at 1.5 mm thickness. Standardized tooth preparations for a full ceramic crown were designed digitally with software (AutoCAD) by placing a 1.0 mm chamfer margin and 1.5 mm occluso-cervical curvature for the crown sample manufacturing. Stylized crowns were chosen to control the thickness of the crown. The axial and occlusal thickness were standardized to 1.5 mm thickness except at the central pit, which was 1.3 mm thick. The STL file for the tooth dies was prepared using software (3Shape TRIOS® Patient Monitoring, Copenhagen, Denmark). The tooth dies were printed with a resin material (NextDent Model 2.0, Vertex-Dental B.V., Soesterberg, The Netherlands) using a 3D printing software (3D Sprint® Client Version 3.0.0.2494) from a 3D printer (NextDent™ 5100, Vertex-Dental B.V., Soesterberg, The Netherlands). The printing layer thickness was 50 µm. Then, a total of twenty-eight (N = 28) stylized crowns were milled out of AmannGirrbach (Amann Girrbach GmbH, Pforzheim, Germany) (n = 7), Cercon HT (Dentsply Sirona, Bensheim, Germany) (n = 7), Cercon XT (Dentsply Sirona, Bensheim, Germany) (n = 7), and Vita YZ XT (Zahnfabrik, Bäd Sackingen, Germany) (n = 7). Following sintering the crowns, sandblasting was performed and they were bonded to the tooth dies with the resin cement (RelyX U-200, 3M ESPE, Seefeld, Germany) and permitted to self-cure under finger pressure for 6 min. The crowns were loaded on the occlusal surface in a universal testing machine (MTS Centurion) with a stainless-steel ball indenter (7 mm radius) with a loading rate of 1 mm/min to contact the stylized crowns on each of the four cusps until failure. A rubber sheet (1.5 mm thickness) was positioned between the crown and indenter, which helped with the load distribution. Statistical analysis was done using SPSS version 20 (IBM Company, Chicago, USA). The fracture loads were analyzed using Dunnett’s T3 test, and the number of cracks was analyzed using the Mann–Whitney U test among the groups. The significant level was set at p value = 0.05. The mean fracture loads were 3086.54 ± 441.74 N, 4804.94 ± 70.12 N, 3317.76 ± 199.80 N, and 2921.87 ± 349.67 N for AmannGirrbac, Cercon HT, Cercon XT, and Vita YZ XT, respectively. The mean fracture loads for the surfaces with the greatest number of cracks (excluding the occlusal surfaces) were on the lingual surface for AmannGirrbach and Cercon HT, on the distal and mesial for Cercon XT, and on the buccal for Vita YZ XT. We found that the AmannGirrbach had the most overall cracks. Cercon XT had the greatest number of occlusal cracks and appeared to be the most shattered. Cercon HT had the least number of cracks. In conclusion, Cercon HT presented the best strength properties, the highest fracture load, and no visible cracks. AmannGirrbach presented the lowest strength properties.
Background. COVID-19 has spread worldwide and caused severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) led to numerous dead cases. However, with the new COVID-19 outbreaks, there is a shortage of personal protective equipment (PPE) especially N95 masks worldwide including Thailand. This issue had placed the health professional in great need of an alternative mask. Aim. This study aimed to measure the fit factor of 3D printed frames by quantitative fit testing (QNFT) to find an alternative facemask by using a mask fitter together with 2 different kinds of the American Society for Testing and Materials (ASTM) level 1 surgical mask. Materials and Methods. Two commonly used surgical masks (Sultan Com-Fit Super Sensitive Ear Loop Mask or “White Mask Group,” not water-resistant, and Sultan Blue Com-Fit Super High Filtration Ear Loop Mask or “Blue Mask Group,” water-resistant) with and without 3D printed frame covering. The fit performance was measured by a quantitative fit test (QNFT) device (PortaCount, model 8048, TSI Incorporated, Minnesota, USA) accepted by the Occupational Safety and Health Administration (OSHA). The PortaCount device, which is based on a miniature continuous flow condensation nucleus counter (CNC), assesses the respiratory fit by comparing the concentration of ambient dust particles outside the surgical mask to the concentration that has leaked into the surgical mask. The ratio of these two concentrations (Cout/Cin) is called the fit factor. A fit factor of a 3D printed frame of at least 100 is required and considered as a pass level. Results. We found that the mask fitter improves the overall performance of surgical masks significantly. The improved performance is comparable to that of N95. Conclusion. The mask fitter improves the performance of surgical masks. The authors suggested that further study on frame material, shape, and expanded sample size would be beneficial to society.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.