Background Haematological malignancies and their treatments are likely to affect SARS-CoV-2 vaccine efficacy. We aimed to evaluate serological response to BNT162b2 vaccine in patients with haematological malignancies by type of treatment. Methods Our national prospective cohort study was done in Lithuania and assessed serological response to one and two BNT162b2 (Comirnaty, Pfizer-BioNTech) vaccine doses in healthy health-care workers and in patients with haematological malignancies. Eligible participants were aged 18 years or older, had received both vaccine doses, and had available biobanked blood samples from before vaccination and after the second dose. Biobanked samples and health data were obtained from Vilnius University Hospital Santaros Klinikos Biobank. Abbott Architect SARS-CoV-2 IgG Quant II chemiluminescent microparticle assay was used to quantify serum anti-SARS-CoV-2-S1 IgG antibody (anti-S1 IgG antibody) concentrations 0–10 days before the first BNT162b2 vaccine, on the day of second immunisation (around day 21), and 7 to 21 days after the second immunisation. Adverse events were assessed by a standardised questionnaire. Breakthrough infections were characterised clinically and by SARS-CoV-2 genotyping whenever possible. This study is registered with ClinicalTrials.gov , NCT04871165 . Findings Between Jan 8 and April 21, 2021, 885 participants with haematological malignancies were included in the study. 857 patients were anti-S1 IgG seronegative at timepoint 0 and constituted the main analysis cohort. The age-matched comparison was made between 315 patients with haematological malignancies who were aged 18–60 years and 67 healthy health-care workers in the same age group. Patients aged 18–60 years with haematological malignancies had lower median anti-S1 IgG antibody responses after two BNT162b2 vaccine doses than did health-care workers of the same age group (median 6961 AU/mL [IQR 1292–20 672] vs 21 395 AU/mL [14 831–33 553]; p<0·0001). Compared with untreated patients with haematological malignancies (n=53; median 5761 AU/mL [629–16 141]), patients actively treated with Bruton tyrosine kinase inhibitors (BTKIs; n=44; 0 AU/mL [0–7]; p<0·0001), ruxolitinib (n=16; 10 AU/mL [0–45]; p<0·0001), venetoclax (n=10; 4 AU/mL [0–1218]; p=0·0005), or anti-CD20 antibody therapy (n=87; 17 AU/mL [1–2319]; p<0·0001) showed particularly poor anti-S1 IgG antibody responses following two BNT162b2 doses. Patients being treated with tyrosine kinase inhibitors (n=41; 10 537 AU/mL [IQR 2335–19 388]) or patients who received autologous haematopoietic stem-cell transplantation (HSCT; n=192; 6203 AU/mL [1451–16 834]) or allogeneic HSCT (n=122; 6304 AU/mL [1120–16 913]) were among the subgroups with the highest numerical responses. Nine SARS-CoV-2 infections and three COVID-19 deaths were observed among fully vaccinated patients with haematological malignancies. ...
The VWF multimer assay by Sebia is easy to perform and can be successfully implemented in any clinical laboratory for second-stage evaluation of VWD. The resolution power of multimer distribution is adequate to correctly classify VWD types 1, 2A, 2B, and 3.
Measuring direct oral anticoagulant (DOAC) concentrations might be necessary in certain clinical situations but is not routinely performed. The DOAC Dipstick is a new rapid test for detecting DOACs in urine. The aim of this study was to evaluate the possible uses and limitations of the DOAC Dipstick and to compare visual analysis and DOASENSE Reader analysis of DOAC Dipstick pads. Plasma and urine samples were collected from 23 patients taking DOACs. DOAC concentrations in plasma and urine were measured by chromogenic substrate assays and in urine also by the DOAC Dipstick. Plasma concentrations were dichotomized at a threshold of ≥30 ng/mL. Patient samples were compared with samples from control individuals not using anticoagulants (n = 10) and with DOASENSE control urines. The Combur-10 test was used to measure parameters that may affect urine color and hence the interpretation of the DOAC Dipstick result. DOAC Dipstick test results were positive in 21/23 patient urine samples at a plasma DOAC concentration of ≥30 ng/mL and in 2/23 patient urine samples at a plasma DOAC concentration of <30 ng/mL. Inter-observer agreement was above 90% for visual analysis of patient urine samples and was 100% for DOASENSE Reader analysis of patient urines and for analysis of control group urines and DOASENSE control urines. Abnormalities in urine color detected by the Combur-10 test did not affect the DOAC Dipstick results. DOAC Dipstick detects DOACs in urine at a plasma threshold of ≥30 ng/mL. Positive DOAC Dipstick results should be confirmed by measuring DOAC plasma concentration.
Accurate diagnosis and classification of von Willebrand disease are essential for optimal management. The von Willebrand factor multimers analysis is in the phenotypic classification, especially in discrepant cases, an integral part of the diagnostic process. The aim of this study was to evaluate the performance of a new Hydragel 11VWF multimer assay (H11VW). Results: Comparison study did not reveal any significant difference between H5VW and H11VW. The assessment of within-subject results, using H5VW and H11VW, demonstrates the reproducibility of the method in both healthy and VWD patients’ samples collected over time, with identical multimeric pattern on densitometric curves.Conclusion: This assay demonstrated acceptable performance, produced within-day results and can be used in routine practice for the visual investigation of gel and quantitative estimation of VWF multimer fractions.
Hepatic cirrhosis is a major health problem across the world, causing high morbidity and mortality. This disease has many etiologies, yet the result of chronic hepatic injury is hepatic fibrosis causing cirrhosis and hepatocellular carcinoma, as the liver’s architecture is progressively destroyed. While liver biopsy is currently the gold standard for fibrosis staging, it has significant disadvantages, leading to a growing interest in non-invasive markers. Direct biomarkers – hyaluronic acid, laminin, collagen type III N-peptide, type IV collagen and cholylglycine – are new and rarely applied in routine clinical practice. This is the case primarily because there is no general consensus regarding the clinical application and effectiveness of the individual biomarkers. The usage of these markers in routine clinical practice could be advantageous for patients with liver fibrosis, requiring a simple blood test instead of a biopsy. The former option would be especially attractive for patients who are contraindicated for the latter. This review summarizes recent findings on direct biomarkers of liver fibrosis and highlights their possible applications and potential benefit for liver fibrosis diagnostics and/or staging.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.