AbstractThe aim of study was to analyze heart rate variability (HRV) after different cardiac valve surgery procedures and the prognostic values of these findings. This study included 101 consecutive patients who underwent surgical implantation for an artificial valve. The mean age of the patients was 62 ± 10 years. An aortic valve was implanted in 65 patients. A mitral valve was implanted in 36 patients. HRV was analyzed from 24 hours Holter electrocardiographic (ECG) records. The time from the operation to the recording of Holter ECG and measuring HRV was 3.8 ± 1.4 months. After discharged from stationary cardiac rehabilitation, all involved patients were contacted to provide data on their health in the follow-up period (33 ± 21 months). A total of 46 patients with an implanted artificial valve had decreased overall HRV or standard deviation of all normal R-R intervals (SDNN) < 93 ms. Patients with an implanted artificial mitral valve had a shorter RR interval (817 ± 122 vs. 863 ± 122ms, p=0.03) and lower values of total power (1166 ± 1888 vs. 2802 ± 3601 ms2, p<0.001) compared to patients with an implanted artificial aortic valve. The results of study show that several months after cardiac surgery, almost half of the patients with an implanted artificial valve have decreased HRV. However, postoperative decreased HRV in those patients have no importance in long-term prediction of mortality rate.
Background. It is known that after coronary artery bypass graft surgery (CABG) heart rate variability (HRV) becomes significantly decreased with a gradual recovery in a few months after surgery. However, literature data about the impact of the off-pump CABG on postoperative HRV are not complete. Therefore, the aim of this study was to analyze postoperative value of HRV in CABG patients operated on with off-pump versus on-pump coronary surgery. Methods. This study included 206 consecutive patients who underwent CABG. Sixty six patients (32%) were operated on off-pump while 140 patients (68%) were operated on using the machine for extracorporal circulation. HRV was analyzed from 24-hours Holter electrocardiogram recordings. Results. No significant differences in postoperative values of HRV variables were found between off-pump versus on-pump CABG patients (Mean RR interval 885 ±
106 versus 879 ± 125 ms, standard deviation of all normal R-R intervals 107 ± 30 versus 105 ± 34 ms, NS, total power 2298 ± 2472 versus 2156 ± 1913 ms2, NS). Conclusions. The results of the study showed that there are no differences in HRV few months after surgery between patients operated on with off-pump versus on-pump CABG.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.