Abstract:The purpose of this study was to assess the ability of an off-centered rectangular design system [ProTaper Next (PTN)] to maintain the original profile of the root canal anatomy. To this end, ProTaper Universal (PTU), Reciproc (R) and WaveOne (WO) systems were used as reference techniques for comparison. Forty clear resin blocks with simulated curved root canals were randomly assigned to 4 groups (n = 10) according to the instrumentation system used: PTN, PTU, R and WO. Color stereomicroscopic images of each block were taken before and after instrumentation. All image processing and data analysis were performed with an open source program (Fiji v.1.47n). Evaluation of canal transportation was obtained for two independent regions: straight and curved portions. Univariate analysis of variance and Tukey's Honestly Significant Difference test were performed, and a cut-off for significance was set at α = 5%. Instrumentation systems significantly influenced canal transportation (p = 0.000). Overall, R induced significantly lower canal transportation compared with WO, PTN and PTU (p = 0.000). The curved portion displayed superior canal transportation compared to the straight one (p = 0.000). The significance of the difference among instrumentation systems varied according to the canal level evaluated (p = 0.000). In its straight portion, R and WO exhibited significantly lower transportation than PTN; whereas in the curved portion, R produced the lowest deviation. PTU exhibited the highest canal transportation at both levels. It can be concluded that PTN produced less canal transportation than PTU and WO; however, R exhibited better centering ability than PTN.
[TFA]) systems in maintaining the original canal profile in straight and curved parts after apical preparations up to size 40. Methods: Resin blocks with simulated curved canals were randomly assigned to five groups: PTU, PTN, R, WO and TFA. Images were captured from each block before and after canal preparation (n=10). Assessment of canal transportation was obtained for the straight and curved parts of the canal. ANOVA followed by Tukey's test was used (α = 5%). Results: Transportation values were increased at the curved part (P = .00). For both canal levels, TFA system induced the lowest mean of canal transportation followed by PTN, R, WO and PTU systems. At the straight portion, transportation for R and TFA systems were similar (P > .05), and these values were significantly lower than for WO, PTN and PTU (P = .00). At the curved portion, TFA resulted in less canal transportation, followed by PTN, R, WO and PTU systems (P = .00). Conclusions: TFA system produced less canal transportation than other systems tested during large apical preparations.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.