The process of air stripping/absorption was studied at pilot scale at temperatures ranging between 23 and 75°C using ammonia in artificial and natural centrate. The process was more effective at high temperatures and became pH insensitive beyond a critical pH, which was found to drop as the operating temperature increased. Thus, at high temperatures, shorter packing height and lower pH are required to achieve the same ammonia removal. The Onda correlations predicted well the mass‐transfer properties of 25 mm (1 in.) and 32 mm (1.25 in.) nominal size packing in the ranges of 40 to 60°C and 53 to 61°C, respectively. The Norman/Sherwood–Holloway correlations predicted well the mass‐transfer properties for the former and poorly underpredieted the latter packing. The Onda correlations are recommended for preliminary design of stripping/absorption systems within the preceding temperature ranges.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.