Somatostatin, integrated in a treatment algorithm, was successful in resolving persistent chylothorax in around 50% of patients. With this strategy, some children may be prevented from undergoing an operation. However, factors predicting successful therapy with somatostatin could not be elicited.
Since the volume of air which is effectively required depends on several factors and varies between patients, the cuffs should be inflated only with the minimum volume of air required to form an effective seal with the respiratory and gastrointestinal tracts and the cuff pressure should be controlled.
ABSTRACT. Objective. Arterial oxygen saturation (SaO 2 ) and arterial carbon dioxide partial pressure (PaCO 2 ) are 2 of the most important respiratory parameters in the treatment of critically ill neonates. Noninvasive monitoring of these parameters is desirable for continuous estimating of the respiratory status and reducing blood loss because of repeated blood gas analyses. Transcutaneous measurement of PCO 2 (PtcCO 2 ) represents a simple and noninvasive technique for continuous monitoring of ventilation. However, sensor preparation, positioning, taping, and repeated changes of the sensor location make the handling difficult and complicate its use in the neonatal care unit. Recently, a new sensor for combined assessment of pulse oximetry oxygen saturation (SpO 2 ) and PtcCO 2 has been introduced (TOSCA Monitor; Linde Medical Sensors, Basel, Switzerland). The monitor combines pulse oximetry and PtcCO 2 measurement in a single ear sensor, which works at 42°C to enhance blood flow in capillaries below the sensor.Methods. In a prospective, open, nonrandomized study of 60 ill neonates, the new ear sensor for combined assessment of SpO 2 and PtcCO 2 at 42°C was tested. The sensor was adapted to the ear of a neonate with a Varihesive layer (Conva Tec; Princeton, NJ). Data obtained from the ear sensor were compared with SpO 2 Finger/Heel , SaO 2 , and PaCO 2 obtained from arterial blood gas in 30 patients and with a capillary blood gas in an additional 30 patients using Bland Altman bias analysis. Data are presented as median (range).Results. The postconceptional age of the patients was 38.3 weeks (range: 28 5/7-40 5/7) in the arterial group and 37.9 weeks (range: 29 6/7-41 0/7) in the capillary group. Age of the newborns studied was 3.5 days (range: 1-28) in the arterial blood sample group (n ؍ 30) and 6 days (range: 2-28) in the capillary blood sample group (n ؍ 30). Patient weight was 3.02 kg (range: 1.5-4.5) in the arterial group and 2.76 kg (range: 1.0 -3.71) in the other group. Three patients had weights of <1500 g. Twentyone of 60 patients were conventionally ventilated, 4 patients received high-frequency oscillation, and 35 were not ventilated. Mean difference (bias) and precision (2 SD of the mean difference) between PtcCO 2 TOSCA and PaCO 2 were ؊0.44 kPa (؊3.21 mm Hg) and 0.82 kPa (6.02 mm Hg) and between PtcCO 2 TOSCA and PcapCO 2 were ؊0.09 kPa (؊0.67 mm Hg) and 1.11 kPa (8.07 mm Hg), respectively. SpO 2 assessment by the TOSCA revealed slightly higher values compared with SaO 2 (bias: ؊0.48%), whereas SpO 2 Finger/Heel values were slightly lower than SaO 2 (bias: 0.52%).Conclusion. The TOSCA monitor with the ear sensor adapted to ears of neonates allows reliable estimation of SaO 2 and PaCO 2 . A potential benefit is the reduction in motion artifacts because of less head movement in newborns and that only a single cable leads form the patient to the monitor. In addition, the sensor is not removed for chest radiograph or for nursing the infant on his or her parent's lap. Long-term studies in a large...
Increased loss of antithrombin is present in children with chylothorax, potentially predisposing these children to an increased risk of thrombosis. Repeated antithrombin substitution should be considered in critically ill children with chylothorax.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.