A diamond microelectrode was used to sensitively, reproducibly and stably record overflow of 5-hydroxytryptamine (5-HT, serotonin) from enterochromaffin cells (EC) of the intenstinal mucosal layer. 5-HT is an important neurotransmitter and paracrine signalling molecule in the gastrointestinal tract. The diamond microelectrode was formed by overcoating a sharpened 76 microm diameter Pt wire with a thin layer of conducting diamond. After insulation with polypropylene, the conically-shaped microelectrode had a diameter of about 10 microm at the tip and 80 microm at the cylindrical portion. The exposed length was 100-200 microm. Continuous amperometry with the microelectrode poised at a detection potential of 700 mV vs. Ag|AgCl was used to measure 5-HT overflow as an oxidation current. 5-HT overflow was elicited by both mechanical and electrical stimulation. Some minor electrode fouling, a common problem with the oxidative detection of 5-HT, was seen for diamond but the response stabilized enabling recording in vitro. Both 5-HT and the paracrine hormone, melatonin, were detected in the extracellular solution. The 5-HT oxidation current increased in the presence of the serotonin transporter (SERT) inhibitor, fluoxetine (1 microM), providing evidence that the oxidation current was associated with 5-HT.
The analysis of chlorinated phenols (2-chlorophenol, 3-chlorophenol, 4-chlorophenol, 2,4-dichlorophenol, 2,4,6-trichlorophenol, pentachlorophenol) in river water was accomplished using off-line solid-phase extraction (SPE) and capillary electrophoresis coupled with electrochemical detection. A key to the sensitive, reproducible, and stable detection of these pollutants was the use of a boron-doped diamond microelectrode in the amperometric detection mode. An off-line SPE procedure was utilized to extract and preconcentrate the pollutants prior to separation and detection, with ENVI-Chrom P, a highly cross-linked styrene-divinylbenzene copolymer, being employed as the sorbent. Pollutant recoveries in the 95-100% range with relative standard deviations of 1-4% were achieved. The diamond microelectrode provided a low and stable background current with low peak-to-peak noise. The oxidative detection of the pollutants was accomplished at +1.05 V vs Ag/AgCl without the need for electrode pretreatment. The method was evaluated in terms of the linear dynamic range, sensitivity, limit of quantitation, response precision, and response stability. A reproducible electrode response was observed during multiple injections of the chlorinated phenol solutions with a relative standard deviation of < or =5.4%. Good electrode response stability was observed over many days of continuous use with no significant electrode deactivation or fouling. The separation efficiencies for all six pollutants were greater than 170,000 plates/m. The minimum concentration detectable for all six ranged from 0.02 to 0.2 ppb (S/N > or = 3) using a 250:1 preconcentration factor.
An emerging research field in electrochemistry today is the preparation, characterization and application of diamond microelectrodes for electroanalytical measurements in biological media. Interest in this new electrode material stems from its outstanding properties: (i) hardness, (ii) low, stable and pH-independent background current, (iii) morphological and microstructural stability over a wide range of potentials, (iv) good electrochemical responsiveness for multiple redox analytes without any conventional pre-treatment and (v) weak molecular adsorption of polar molecules that leads to a high level of resistance to response deactivation and electrode fouling. Diamond electrodes have advanced in recent years from being simply a scientific curiosity into a viable material for electroanalysis. In this article, we highlight the current state of progress by our laboratory and others on the preparation, study of the basic electrochemical properties, and application of this new type of microelectrode for in vitro electroanalytical measurements, and discuss some of the remaining challenges.
This study was designed to test the hypothesis that the transient receptor potential vanilloid type 1 (TRPV1) channel, expressed primarily in sensory nerves, and substance P (SP), released by sensory nerves, play a protective role against lipopolysaccharide (LPS)-induced hypotension. LPS (10 mg/kg iv) elicited tachycardia and hypotension in anesthetized male Wistar rats, which peaked at 10 min and gradually recovered 1 h after the injection. Blockade of TRPV1 with its selective antagonist capsazepine (CAPZ, 3 mg/kg iv) impaired recovery given that the fall in mean arterial pressure (MAP) was greater 1 h after CAPZ plus LPS injections compared with LPS injection alone (45 +/- 5 vs. 25 +/- 4 mmHg, P < 0.05). Blockade of the neurokinin 1 (NK1) receptor with its selective antagonists RP-67580 (5 mg/kg iv) or L-733,060 (4 mg/kg iv) prevented recovery, considering that falls in MAP were not different 1 h after injections of NK1 antagonists plus LPS from their peak decreases (66 +/- 9 vs. 74 +/- 5 mmHg or 60 +/- 7 vs. 69 +/- 3 mmHg, respectively, P > 0.05). LPS increased plasma SP, norepinephrine (NE), and epinephrine (Epi) levels compared with vehicles, and the increases in plasma SP, NE, and Epi were significantly inhibited by CAPZ or RP-67580. The survival rate at 24 or 48 h after LPS injection (20 mg/kg ip) was lower in conscious rats pretreated with CAPZ or RP-67580 compared with rats treated with LPS alone (P < 0.05). Thus our results show that the TRPV1, possibly via triggering release of SP which activates the NK1 and stimulates the sympathetic axis, plays a protective role against endotoxin-induced hypotension and mortality, suggesting that TRPV1 receptors are essential in protecting vital organ perfusion and survival during the endotoxic condition.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.