Background The Silk Vista Baby (SVB, BALT) is a first-in-class flow-diverter device delivered using a 0.017” microcatheter, designed for the treatment of intracranial aneurysms, including those in small diameter vessels. This study reports a systematic literature review (SLR) to evaluate the safety and efficacy of using SVB to treat intracranial aneurysms in vessels less than 3.5 mm in diameter. Methods We performed a PRISMA-compliant SLR to evaluate the outcomes of SVB in the treatment of aneurysms in small intracranial vessels. Primary outcomes were occlusion status and major stroke, and secondary outcomes included all-cause mortality, procedure-related neurologic death, and post-operative aneurysm rupture. Data were expressed as descriptive statistics only. Results A total of four studies, including 163 patients with 173 intracranial aneurysms, were included. The most common aneurysm locations were the anterior cerebral artery (24.9% [43/173]), the middle cerebral artery (24.3% [42/173]), and the anterior communicating artery (23.1% [40/173]). Parent artery diameter ranged from 0.9 mm to 3.6 mm, and 29% were acutely or previously ruptured aneurysms. Overall, complete or near-complete occlusion was 72.1% on early-term follow-up. Mortality rate among the studies was 2.5%, with 3 instances adjudicated as neurologic deaths (1.8%). Major stroke was noted in 1.2% of cases, and branch occlusion or stent thrombus formation in 5.5%. Conclusion Our review suggests that SVB is a safe and effective treatment for intracranial aneurysms in small vessels. Further prospective and comparative studies with patient outcome data specific to aneurysm location are needed to confirm the safety and efficacy of SVB.
BACKGROUND:Treatment of small-caliber vessel lesions using flow diverters remains challenging because of vasculature's narrow luminal diameter and tortuosity. This in turn makes navigation and delivery of conventional devices with standard microcatheters more difficult. The Silk Vista Baby (SVB, Balt) flow diversion device was designed for ease of use in vessels with a smaller diameter, distal lesions, and 0.017″ microcatheter delivery systems.OBJECTIVE:To report the outcomes of the SVB device on the treatment of posterior inferior cerebellar artery (PICA) aneurysms.METHODS:Databases from different centers were retrospectively reviewed for PICA aneurysms treated with SVB. Demographic information, clinical presentation, radiographic characteristics, procedural complications, and immediate postprocedure outcomes were obtained.RESULTS:Fourteen patients harboring 15 true PICA aneurysms were treated between January 2019 and June 2021. Nine were female (n = 9/14; 64.2%), and the mean age was 51 ± 14.9 years. Most patients had previously ruptured aneurysms, treated by another endovascular technique. Six aneurysms were located distally (n = 6/15; 40%). The mean neck size was 3 mm (SD 1.35, range 2.5-5 mm), whereas the mean PICA diameter was 1.6 mm (SD 0.26, range 1.5-1.7 mm). The mean length of follow-up was 6 months (SD 8.28, range 4.5-16 months). Treatment-related adverse events included 1 case of transient hypoesthesia. Two additional events were reported, but adjudicated as unrelated to the procedure. Complete occlusion, measured as Raymond-Roy class I, was achieved in all cases.CONCLUSION:The SVB device was safely and effectively used in the treatment of PICA aneurysms. The smaller delivery system profile reduces the risk of procedure complications and creates new treatment options for distal lesions.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.