The parameters of a spoiled gradient-echo (SPGR) pulse sequence have been optimized for in vivo localization of a focused ultrasound beam. Temperature elevation was measured by using the proton resonance frequency shift technique, and the phase difference signal-to-noise ratio (SNR delta phi) was estimated in skeletal muscle and kidney cortex in 10 rabbits. Optimized parameters included the echo time equivalent to T2* of the tissue, the longest repetition time possible with a 20-s sonication, and the flip angle equivalent to the Ernst angle. Optimal SPGR phase imaging can detect a sonication beam with a peak phase difference of 0.55 radian, which corresponds to a temperature elevation of 7.3 degrees C. The sonication beam can be localized within one voxel (0.6 x 0.6 x 5 mm3) at power levels that are below the threshold for thermal damage of the tissue.
Minimally invasive applications of thermal and mechanical energy to selective areas of the human anatomy have led to significant advances in treatment of and recovery from typical surgical interventions. Image-guided focused ultrasound allows energy to be deposited deep into the tissue, completely noninvasively. There has long been interest in using this focal energy delivery to block nerve conduction for pain control and local anesthesia. In this study, we have performed an in vitro study to further extend our knowledge of this potential clinical application. The sciatic nerves from the bullfrog (Rana catesbeiana) were subjected to focused ultrasound (at frequencies of 0.661MHz and 1.986MHz) and to heated Ringer’s solution. The nerve action potential was shown to decrease in the experiments and correlated with temperature elevation measured in the nerve. The action potential recovered either completely, partially, or not at all, depending on the parameters of the ultrasound exposure. The reduction of the baseline nerve temperature by circulating cooling fluid through the sonication chamber did not prevent the collapse of the nerve action potential; but higher power was required to induce the same endpoint as without cooling. These results indicate that a thermal mechanism of focused ultrasound can be used to block nerve conduction, either temporarily or permanently.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.