IMPORTANCE Nonmelanoma skin cancers (NMSCs) are primarily diagnosed through paraffin section histologic analysis of skin biopsy specimens that requires days to weeks before a formal diagnosis is reported. Two-photon fluorescence microscopy (TPFM) has the potential for point-of-care diagnosis of NMSC and other dermatologic conditions, which could enable same-visit diagnosis and treatment.OBJECTIVE To demonstrate that TPFM imaging of NMSC can occur within minutes of obtaining biopsies and provide similar histological features to those of conventional histology and evaluate TPFM diagnostic performance with respect to conventional histology. DESIGN, SETTING, AND PARTICIPANTSThis comparative effectiveness pilot study examined 29 freshly excised biopsies from confirmed NMSC lesions in patients presenting for treatment. Biopsies underwent imaging immediately with TPFM on site at Rochester Dermatologic Surgery (Victor, New York) between October 2019 and August 2021. The imaged biopsies were subsequently submitted for paraffin histology to produce coregistered images. Twelve of these coregistered image pairs (41.4%) were used as a training set. Fifteen (51.7%) were used in a masked evaluation by a board-certified dermatopathologist. Two (6.9%) were excluded from the study before evaluation because they could not be coregistered.MAIN OUTCOMES AND MEASURES Sensitivity, specificity, and accuracy of TPFM for NMSC biopsies were evaluated compared with conventional histology.RESULTS Fourteen of the 15 biopsy specimens (93.3%) in the evaluation set were identically diagnosed with TPFM and paraffin histology. The TPFM had 100% sensitivity (95% CI, 48%-100%), 100% specificity (95% CI, 69%-100%), and 100% accuracy (95% CI, 78%-100%) for basal cell carcinoma diagnosis. For squamous cell carcinoma diagnosis, TPFM had 89% sensitivity (95% CI, 52%-100), 100% specificity (95% CI, 54%-100%), and 93% accuracy (95% CI, 68%-100%). For overall NMSC diagnosis, TPFM had a 93% sensitivity (95% CI, 66%-100%), 100% specificity (95% CI, 3%-100%), and 93% accuracy (95% CI, 68%-100%). Examination of the 1 discordant pair revealed mismatched imaging planes as the source of error. CONCLUSIONS AND RELEVANCEThe results of this comparative effectiveness pilot study suggest that TPFM captures histological characteristics of NMSC that are present in conventional histology, which reveals its potential as a rapid, point-of-care diagnostic alternative that does not need extensive sample preparation or retraining for image evaluation. Further validation of TPFM imaging performed for a larger cohort is needed to fully evaluate its diagnostic accuracy and potential effect within the field.
Conventional two-photon microscopes use photomultiplier tubes, which enable high sensitivity but can detect relatively few photons per second, forcing longer pixel integration times and limiting maximum imaging rates. We introduce novel detection electronics using silicon photomultipliers that greatly extend dynamic range, enabling more than an order of magnitude increased photon detection rate as compared to state-of-the-art photomultiplier tubes. We demonstrate that this capability can dramatically improve both imaging rates and signal-to-noise ratio (SNR) in two-photon microscopy using human surgical specimens. Finally, to enable wider use of more advanced detection technology, we have formed the OpenSiPM project, which aims to provide open source detector designs for high-speed two-photon and confocal microscopy.
. Significance: Two-photon and confocal microscopy can obtain high frame rates; however, mosaic imaging of large tissue specimens remains time-consuming and inefficient, with higher imaging rates leading to a larger fraction of time wasted translating between imaging locations. Strip scanning obtains faster mosaic imaging rates by translating a specimen at constant velocity through a line scanner at the expense of more complex stitching and geometric distortion due to the difficulty of translating at completely constant velocity. Aim: We aim to develop an approach to mosaic imaging that can obtain higher accuracy and faster imaging rates while reducing computational complexity. Approach: We introduce an approach based on scanner-synchronous position sampling that enables subwavelength accurate imaging of specimens moving at a nonuniform velocity, eliminating distortion. Results: We demonstrate that this approach increases mosaic imaging rates while reducing computational complexity, retaining high SNR, and retaining geometric accuracy. Conclusions: Scanner synchronous strip scanning enables accurate, high-speed mosaic imaging of large specimens by reducing acquisition and processing time.
Microscopy with ultraviolet surface excitation (MUSE) typically has an optical sectioning thickness significantly larger than standard physical sectioning thickness, resulting in increased background fluorescence and higher feature density compared to formalin-fixed, paraffin-embedded physical sections. We demonstrate that high-index immersion with angled illumination significantly reduces optical sectioning thickness through increased angle of refraction of excitation light at the tissue interface. We present a novel objective dipping cap and waveguide-based MUSE illuminator design with high-index immersion and quantify the improvement in optical sectioning thickness, demonstrating an e-1 section thickness reduction to 6.67 µm in tissue. Simultaneously, the waveguide illuminator can be combined with high or low magnification objectives, and we demonstrate a 6 mm2 field of view, wider than a conventional 10x pathology objective. Finally, we show that resolution and contrast can be further improved using deconvolution and focal stacking, enabling imaging that is robust to irregular surface profiles on surgical specimens.
Microscopy with ultraviolet surface excitation (MUSE) typically has an optical sectioning thickness significantly larger than standard physical sectioning thickness, resulting in increased background fluorescence and higher feature density compared to formalin-fixed, paraffin-embedded physical sections. We demonstrate that high-index immersion with angled illumination significantly reduces optical sectioning thickness through increased angle of refraction of excitation light at the tissue interface. We present a novel objective dipping cap and waveguide-based MUSE illuminator design with high-index immersion and quantify the improvement in optical sectioning thickness, demonstrating an e −1 section thickness reduction to 6.67 µm in tissue. Simultaneously, the waveguide illuminator can be combined with high or low magnification objectives, and we demonstrate a 6 mm 2 field of view, wider than a conventional 10x pathology objective. Finally, we show that resolution and contrast can be further improved using deconvolution and focal stacking, enabling imaging that is robust to irregular surface profiles on surgical specimens.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.