Continuous vital signal monitoring is becoming more relevant in preventing diseases that afflict a large part of the world’s population; for this reason, healthcare equipment should be easy to wear and simple to use. Non-intrusive and non-invasive detection methods are a basic requirement for wearable medical devices, especially when these are used in sports applications or by the elderly for self-monitoring. Arterial blood pressure (ABP) is an essential physiological parameter for health monitoring. Most blood pressure measurement devices determine the systolic and diastolic arterial blood pressure through the inflation and the deflation of a cuff. This technique is uncomfortable for the user and may result in anxiety, and consequently affect the blood pressure and its measurement. The purpose of this paper is the continuous measurement of the ABP through a cuffless, non-intrusive approach. The approach of this paper is based on deep learning techniques where several neural networks are used to infer ABP, starting from photoplethysmogram (PPG) and electrocardiogram (ECG) signals. The ABP was predicted first by utilizing only PPG and then by using both PPG and ECG. Convolutional neural networks (ResNet and WaveNet) and recurrent neural networks (LSTM) were compared and analyzed for the regression task. Results show that the use of the ECG has resulted in improved performance for every proposed configuration. The best performing configuration was obtained with a ResNet followed by three LSTM layers: this led to a mean absolute error (MAE) of 4.118 mmHg on and 2.228 mmHg on systolic and diastolic blood pressures, respectively. The results comply with the American National Standards of the Association for the Advancement of Medical Instrumentation. ECG, PPG, and ABP measurements were extracted from the MIMIC database, which contains clinical signal data reflecting real measurements. The results were validated on a custom dataset created at Neuronica Lab, Politecnico di Torino.
Background Acute Kidney Injury (AKI), a frequent complication of pateints in the Intensive Care Unit (ICU), is associated with a high mortality rate. Early prediction of AKI is essential in order to trigger the use of preventive care actions. Methods The aim of this study was to ascertain the accuracy of two mathematical analysis models in obtaining a predictive score for AKI development. A deep learning model based on a urine output trends was compared with a logistic regression analysis for AKI prediction in stages 2 and 3 (defined as the simultaneous increase of serum creatinine and decrease of urine output, according to the Acute Kidney Injury Network (AKIN) guidelines). Two retrospective datasets including 35,573 ICU patients were analyzed. Urine output data were used to train and test the logistic regression and the deep learning model. Results The deep learning model defined an area under the curve (AUC) of 0.89 (± 0.01), sensitivity = 0.8 and specificity = 0.84, which was higher than the logistic regression analysis. The deep learning model was able to predict 88% of AKI cases more than 12 h before their onset: for every 6 patients identified as being at risk of AKI by the deep learning model, 5 experienced the event. On the contrary, for every 12 patients not considered to be at risk by the model, 2 developed AKI. Conclusion In conclusion, by using urine output trends, deep learning analysis was able to predict AKI episodes more than 12 h in advance, and with a higher accuracy than the classical urine output thresholds. We suggest that this algorithm could be integrated in the ICU setting to better manage, and potentially prevent, AKI episodes. Graphic abstract
Smart devices are more and more present in every aspect of everyday life. From smartphones, which are now like mini-computers, through systems for monitoring sleep or fatigue, to specific sensors for the recording of vital parameters. A particular class of the latter regards health monitoring. Indeed, through the use of such devices, several vital parameters can be acquired and automatically monitored, even remotely. This paper presents the second generation of VITAL-ECG, a smart device designed to monitor the most important vital parameters as a "one touch" device, anywhere, at low cost. It is a wearable device that coupled with a mobile app can track bio-parameters such as: electrocardiogram, SpO 2 , skin temperature, and physical activity of the patient. Even if it not yet a medical device, a comprehensive comparison with a golden standard electrocardiograph is presented to demonstrate the quality of the recorded signals and the validity of the proposed approach.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.