Reoperations for deteriorated stentless bioprostheses are quite challenging procedures. Calcification of the aortic annulus and of the subcoronary root makes often impossible the removal of the failed valve, living a complex Bentall operation or a high-risk transcatheter aortic valve implantation valve-in-valve procedure as the only options, particularly in cases of small-size prostheses. The Perceval sutureless prosthesis (LivaNova PLC, London, UK) can be a valid alternative for failed stentless valve replacement. We report our experience with 3 complex cases of degenerated Sorin Pericarbon Freedom prosthesis treated successfully by means of Perceval sutureless implantation and demonstrating the reproducibility and the safety of this surgical approach.
False aneurysm occurring after replacement of ascending aorta by a vascular prosthesis is a rare, but life-threatening complication. In spite of advances in endovascular techniques, surgery remains the treatment of choice in the majority of cases. We report the case of a huge pseudoaneurysm caused by late dehiscence of the right coronary ostium-aortic tubular graft anastomosis, occurred 30 years after replacement of aortic valve and ascending aorta by classical Bentall operation. A fistula originating from the aneurysmal sac extended across the sternum into the thoracic subcutaneous soft tissues and gave rise to a pulsatile mass well appreciable on the anterior chest wall. The surgical treatment, consisting of partial resection of the aortic tubular graft and sternal reconstruction was effective and uneventful.
Objective Stentless aortic valves have shown superior hemodynamic performance and faster left ventricular mass regression compared to stented bioprostheses. Yet, controversies exist concerning the durability of stentless valves. This case-matched study compared short- and long-term clinical outcomes of stentless LivaNova-Sorin Pericarbon Freedom™ (SPF) and stented Carpentier-Edwards Perimount (CEP) aortic prostheses. Methods From 2003 through 2006, 134 consecutive patients received aortic valve replacement with SPF at our institution. This cohort was matched, according to 20 preoperative clinical parameters, with a control group of 390 patients who received CEP prosthesis during the same time. The resulting 55 + 55 matched patients were analyzed for perioperative results and long-term clinical outcomes. Results Early mortality was 0% for both groups. Lower transvalvular gradients were found in the SPF group (10.6 ± 2.9 versus 15.7 ± 3.1 mmHg, P < 0.001). Overall late mortality (mean follow-up: 10.03 years) was similar for both groups (50.1% versus 42.8%, P = 0.96). Freedom from structural valve degeneration (SVD) at 13 years was similar for both groups (SPF = 92.3%, CEP = 73.9%, P = 0.06). Freedom from aortic valve reinterventions did not differ (SPF = 92.3%, CEP = 93.5%, P = 0.55). Gradients at 13-year follow-up remained significantly lower in SPF group (10.0 ± 4.5 versus 16.2 ± 9.5 mmHg, P < 0.001). Incidence of acute bacterial endocarditis (ABE) and major adverse cardiovascular and cerebrovascular events (MACCE) was similar. Conclusions SPF and CEP demonstrated comparable long-term outcomes related to late mortality, SVD, aortic valve reinterventions, and incidence of ABE and MACCE. Superior hemodynamic performance of SPF over time can make this valve a suitable choice in patients with small aortic root and large body surface area.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.