Our study supports the contention that atrial fibrillation after coronary surgery is associated with pre-existing histopathologic changes of the right atrium. Patients randomly allocated to off-pump coronary artery bypass grafting procedures showed a similar rate of atrial fibrillation and a similar relationship to atrial histology as did those exposed to cardiopulmonary bypass. Cardiopulmonary bypass did not cause additional changes in tested histology variables.
Central Message The modern treatment for type A aortic dissection requires careful planning, a wide range of expertise, and a multidisciplinary approach. Specialized aortic centers might be the solution.
Background and Aim of the Study
To report early clinical outcomes of the frozen elephant trunk (FET) technique for the treatment of complex aortic diseases after transition from conventional elephant trunk.
Methods
A single‐center, retrospective study of patients who underwent hybrid aortic arch and FET repair for aortic arch and/or proximal descending aortic aneurysms, acute and chronic Stanford type A aortic dissection with arch and/or proximal descending involvement, Stanford type B acute and chronic aortic dissections with retrograde aortic arch involvement.
Results
Between December 2017 and May 2020, 70 consecutive patients (62.7 ± 10.6 years, 59 male) were treated: 41 (58.6%) for emergent conditions and 29 (41.4%) for elective. Technical success was 100%. In‐hospital mortality was 14.2% (n = 12, 17.1% emergent vs. 10.3% elective, P = NS); 2 (2.9%) major strokes; 1 (1.4%) spinal cord injury. Mean follow‐up was 12.5 months (interquartile range, 3.7–22.3). Overall survival at 3, 6, 12, and 24 months was 90% (95% confidence interval [CI], 83.2—97.3), 85.6% (95% CI, 77.7–94.3), 79.1% (95% CI, 69.9–89.5), 75.6% (95% CI, 65.8–86.9) and 73.5% (95% CI, 63.3–85.3). There were no aortic re‐interventions and no distal stent graft‐induced new entry (dSINE); 5 patients with residual type B dissection underwent TEVAR completion.
Conclusions
In a real‐world setting, FET with Thoraflex Hybrid demonstrated feasibility and good clinical outcomes, even in emergent setting. Our implant technique optimize cerebral perfusion reporting good results in terms of neurological complications. Techniques to perfect the procedure and to reduce remaining risks, and consensus on considerations such as standardized cerebral protection need to be reported.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.