Intracavity ultrasound transducer handles are not routinely immersed in liquid high-level disinfectants. We show that residual bacteria, including pathogens, persist on more than 80% of handles that are not disinfected, whereas use of an automated device reduces contamination to background levels. Clinical staff should consider the need for handle disinfection.Infect Control Hosp Epidemiol 2015;36(5): [581][582][583][584] Ultrasound transducers that contact broken skin or mucous membranes are considered semicritical devices and should undergo high-level disinfection (HLD) between patients. 1 Studies have shown residual contamination on ultrasound transducers when HLD is not performed 2,3 and cases of hepatitis B and C infection have been reported where transmission was thought to have been caused by improper reprocessing of ultrasound transducers. 4,5 HLD methods that involve soaking ultrasound transducers in liquid chemicals, such as glutaraldehyde or ortho-phthalaldehyde, do not typically disinfect the handle. Some major manufacturers specifically advise against submersion of the handle owing to the transducer not being fully sealed. There are no clear recommendations on whether transducer handles should be disinfected, nor is there any consensus on the risk that contaminated transducer handles might pose to patients.Although full immersion of transducers in liquid is not generally possible, approaches that allow the HLD of the entire transducer are now available. This study surveyed the residual contamination on transducer handles when not disinfected (routine soaking method) and also assessed the efficacy of an automated disinfection device capable of disinfecting both heads and handles of ultrasound transducers. methodsThis study was a prospective, bi-centric, cross-sectional study, performed at an ultrasound clinic and public hospital. No patients were excluded and no patient data were collected so the study did not require ethics approval. Following routine ultrasound procedures, all transducers were cleaned with detergent and water and were dried with paper towels. Handle samples were then collected from 2 study groups after the handles were subjected to different disinfection methods. Groups were sampled sequentially in randomized order.The first group of transducers (hereafter referred to as "glutaraldehyde disinfection of head only" [GDHO]) underwent reprocessing according to the existing protocol at the clinic where the head of the transducer was soaked in a 2.4% solution of glutaraldehyde for 20 minutes at room temperature. Transducer handles were not disinfected (per normal practice).The second group of transducers (hereafter referred to as "automated disinfection of head and handle" [ADHH]) were subjected to HLD with an automated disinfection system that disinfects the entire transducer including the handle (trophon EPR; Nanosonics). The device was operated according to the manufacturer's instructions for use.Matched control samples (shams) were collected to quantify contamination occurring during...
Automated, hydrogen peroxide-based disinfection devices offer an alternative to manual ultrasound probe disinfection technologies. Such devices reduce the risks of operator error and can improve patient and operator safety by preventing exposure to toxic chemicals. The adoption of next-generation disinfection devices may help to decrease infection risk and improve patient safety.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.