Corrosion is a significant damage in many reinforced concrete structures, mainly in coastal areas. The oxidation of embedded iron or steel elements degrades rebar, producing a porous layer not adhered to the metallic surface. This process could completely destroy rebar. In addition, the concrete around the metallic targets is also damaged, and a dense grid of fissures appears around the oxidized elements. The evaluation of corrosion is difficult in early stages, because damage is usually hidden. Non-destructive testing measurements, based on non-destructive testing (NDT) electric and magnetic surveys, could detect damage as consequence of corrosion. The work presented in this paper is based in several laboratory tests, which are centered in defining the effect of different corrosion stage on ground penetrating radar (GPR) signals. The analysis focuses on the evaluation of the reflected wave amplitude and its behavior. The results indicated that an accurate analysis of amplitude decay and intensity could most likely reveal an approach to the state of degradation of the embedded metallic targets because GPR images exhibit characteristics that depend on the effects of the oxidized rebar and the damaged concrete. These characteristics could be detected and measured in some cases. One important feature is referred to as the reflected wave amplitude. In the case of corroded targets, this amplitude is lower than in the case of reflection on non-oxidized surfaces. Additionally, in some cases, a blurred image appears related to high corrosion. The results of the tests highlight the higher amplitude decay of the cases of specimens with corroded elements.
Summary
Combined non‐destructive techniques are applied in the study of a historical building in Barcelona. Santa Maria del Mar is a magnificent Mediterranean gothic church built between 1329 and 1383. Two of the most important characteristics of this building are the slender columns and the almost flat rooftop. This structure, used to create a visual impression of a unique space, transmits high loads to the tall columns. Previous to restoration, vaults, roofs, and columns were extensively assessed with non‐destructive tests, in order to improve the knowledge of those structures. This information will be used in further simulations to analyse load distributions at each part of the structure. Ground and floor were also studied. The analysis of the columns was based on ground‐penetrating radar (GPR) surveys and on seismic tomography. Finally, the dynamic behaviour of the structure was determined by seismic monitoring of the main nave and the bell tower. Results obtained at the radar survey highlight the existence of unexpected anomalies in homogeneous materials, supporting the hypothesis of an inner structure between arches and roof composed by hollow elements. Seismic tomography defined the inner geometry of the columns and detected some damage or lower quality stone in various zones. Seismic monitoring established the perfect junction between the bell tower and the main nave. GPR survey on the floor allowed detecting a large number of graves, and some images suggest the existence of large underground walls and some of the foundations of the main façade.
Deterioration of concrete structure is consequence of aging, applied loads and weathering. In this paper, several laboratory tests were presented, compared to computational models and a field test case study. The purpose of the laboratory measurements is the analysis of the results in the case of different size cracks in concrete beams, filled with several materials.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.