ObjectiveTo compare mono- and bi-exponential T2* analysis in healthy and degenerated Achilles tendons using a recently introduced magnetic resonance variable-echo-time sequence (vTE) for T2* mapping.MethodsTen volunteers and ten patients were included in the study. A variable-echo-time sequence was used with 20 echo times. Images were post-processed with both techniques, mono- and bi-exponential [T2*m, short T2* component (T2*s) and long T2* component (T2*l)]. The number of mono- and bi-exponentially decaying pixels in each region of interest was expressed as a ratio (B/M). Patients were clinically assessed with the Achilles Tendon Rupture Score (ATRS), and these values were correlated with the T2* values.ResultsThe means for both T2*m and T2*s were statistically significantly different between patients and volunteers; however, for T2*s, the P value was lower. In patients, the Pearson correlation coefficient between ATRS and T2*s was −0.816 (P = 0.007).ConclusionThe proposed variable-echo-time sequence can be successfully used as an alternative method to UTE sequences with some added benefits, such as a short imaging time along with relatively high resolution and minimised blurring artefacts, and minimised susceptibility artefacts and chemical shift artefacts. Bi-exponential T2* calculation is superior to mono-exponential in terms of statistical significance for the diagnosis of Achilles tendinopathy.Key Points• Magnetic resonance imaging offers new insight into healthy and diseased Achilles tendons• Bi-exponential T2* calculation in Achilles tendons is more beneficial than mono-exponential• A short T2* component correlates strongly with clinical score• Variable echo time sequences successfully used instead of ultrashort echo time sequences
The aim of this study was to investigate T₂* in the Achilles tendon (AT), in vivo, using a three-dimensional ultrashort time echo (3D-UTE) sequence, to compare field strength differences (3 and 7 T) and to evaluate a regional variation of T₂* in healthy and pathologic tendon. Ten volunteers with no history of pain in the AT and five patients with chronic Achilles tendinopathy were recruited. 3D-UTE images were measured with the following echo times, at echo time = [0.07, 0.2, 0.33, 0.46, 0.59, 0.74, 1.0, 1.5, 2.0, 4.0, 6.0, and 9.0 ms]. T₂* values in the AT were calculated by fitting the signal decay to biexponential function. Comparing volunteers between 3 and 7 T, short component T(2s)* was 0.71 ± 0.17 ms and 0.34 ± 0.09 ms (P < 0.05); bulk long component T(2l)* was 12.85 ± 1.87 ms and 10.28 ± 2.28 ms (P < 0.05). In patients at 7 T, bulk T(2s)* was 0.53 ± 0.17 ms (P = 0.045, compared to volunteers), T(2l)* was 11.49 ± 4.28 ms (P = 0.99, compared to volunteers). The results of this study suggest that the regional variability of AT can be quantified by T₂* in in vivo conditions. Advanced quantitative imaging of the human AT using a 3D-UTE sequence may provide additional information to standard clinical imaging. Finally, as the preliminary patient data suggest, T(2s)* may be a promising marker for the diagnosis of pathological changes in the AT.
Long-term clinical outcome in patients 7.9 years after AOT was good, but did not correlate with morphological and biochemical imaging results except for T2-mapping.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.