Remifentanil in high doses, as the single agent for patient preparation for awake fiberoptic intubation seems to improve intubating conditions, quality and reliability of the procedure. However, a higher incidence of recall is to be expected.
Impending upper airway obstruction due to odontogenic facial and cervical spreading infection is a potential fatal situation that requires urgent treatment. In particular, securing the threatened airway is a priority and a precondition to the pressing need for surgery. The best approach to establish the difficult airway is awake fiberoptic intubation or scheduled tracheotomy under local anesthesia. We report a critical case of severe swelling of the neck in a morbidly obese patient with no alternative to awake fiberoptic intubation. The primary goals of optimal safety for the patient and appropriate intubating conditions for the anesthesiologist made us to consider a new method of patient medication.
Purpose To compare the clinical judgement of electroencephalogram (EEG)-naïve anesthesiologists with an EEG-based measurement of anesthetic depth (AD) using the NarcotrendÒ monitor. Methods In this prospective cohort study including 600 patients, AD during stable anesthesia was assessed by clinical judgement of the attending, EEG-blinded anesthesiologist (using a scale staging the AD as midadequate, adequate but fairly deep, or adequate but fairly light) and by simultaneously recorded Narcotrend measurements. Results In 42% of patients (n = 250), the anesthesiologist's clinical judgement was in agreement with anesthetic levels as measured by the Narcotrend monitor. In 46% of patients (n = 274), the anesthesiologist's judgement and the Narcotrend monitor differed by one AD level (minor discordance). Major discordance was observed in 76 (13%) measurements (judged deeper than measured, n = 29 [5%]; judged lighter than measured, n = 47 [8%]). In 7% of patients (n = 44), the Narcotrend index was outside the limits of adequate AD (too deep, n = 28 [5%]; too superficial, n = 16 [3%]). The overall level of agreement between the anesthesiologist's judgement and the Narcotrend monitor was not statistically significant (Cohen's kappa,-0.039; P = 0.17). Using a random forests algorithm, age, mean blood pressure, the American Society of Anesthesiologists classification, body mass index, and frailty were the variables with the highest relative feature importance to predict the level of agreement. Conclusion These results suggest that clinical judgement of AD during stable anesthesia was not in agreement with EEG-based assessment of anesthetic depth in 58% of cases. Nevertheless, this finding could be influenced by the lack of validated scales to clinically judge AD. Trial registration www.clinicaltrials.gov (NCT02766894); registered 10 May, 2016.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.