An analysis was performed of the microbiological laboratory quality control data for the past 9 years (1985-1993). Bacterial contamination was detected in 100 of 25,171 tested blood components. Single-donor platelet concentrates had a contamination incidence of 25 in 5889 (0.42%); whole blood samples were contaminated at a rate of 1 in 2973 (0.03%) and red cell concentrates at a rate of 73 in 15,317 (0.48%); of 992 samples of fresh frozen plasma only 1 was contaminated (0.1%). Gram-positive staphylococci comprised 75% of cases and Gram-negative rods 10%. This frequency of laboratory-detected bacterial contamination contrasts with the low rate of transfusion-associated septicaemic events.
Background: Fresh frozen plasma (FFP) is exposed to numerous factors affecting the quality and stability of coagulation factors during blood collection, preparation and storage. In 1995 the European ‘Guide to the preparation, use and quality assurance of blood components’ extended the shelf-life of FFP from 12 to 24 months and concurrently reduced the storage temperature from –30 to –40 °C. Four years later, the European guidelines amended the storage regulations and permitted a 24-month shelf-life at –30 °C. This new regulation of FFP led us to the question whether storage over 3 years at –40 °C could be performed without relevant loss in coagulation factor activity. Due to missing data, a multicenter study was carried out in 7 different quality control (QC) laboratories of the Bavarian Red Cross Blood Transfusion Service. The aim of our study was to obtain selected stability data of the coagulation factors FV, FVIII:C and FXI as well as of the major inhibitor antithrombin III (AT III) over a storage period of more than 3 years at –40 °C. Material and Methods: 12 plasma units – 3 of each ABO blood group – derived from CPD whole blood were processed according to current national and European guidelines. The plasma units were aliquoted and frozen within 18 h after donation at below –30 °C. The storage temperature was held between –38 and –42 °C during the total storage period of 37 months. In the long-term storage, 4 parameters of the coagulation system were determined in aliquots in 7 different QC laboratories. One-stage coagulometric methods were used to determine coagulation factors, and the determination of AT III inhibitor activity was done by a chromogenic method. After the 1st month of storage, each plasma was tested for specific activity. Thereafter, follow-up testing was performed in 4-month periods. Results: The evaluated coagulation parameters show an acceptable stability during the total storage period if ABO blood groups are not taken into consideration. There was no statistically significant loss in activity for FXI and AT III at the end of the storage period in comparison to the initial values, 101.5% for FXI (pFXI = 0.17) and 101% for AT III (pAT III = 0.66). The loss in FV and in FVIII:C activities was 0.6 and 9%, respectively. Both results indicate a statistically significant reduction (t test: pFV = 0.048; pFVIII:C = 0.033). Similar results were obtained taking ABO blood grouping into account, with the exceptions of blood group A where AT III showed an increase of 11% over baseline values and of blood group O where FXI showed an increase of 11.2% over average coagulation activities. There were no differences in the coagulation activities of blood groups B and AB over the storage period. Conclusions: The results show that, under these storage conditions, the recovery of coagulation parameters in FFP is not reduced below 70% of the starting activity and stays in acceptable ranges. For FXI and AT III we did not find any significant reduction. However, for FV and FVIII:C a significant reduction...
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.