ABSTRACT. Mutations in the fibroblast growth factor receptor-3 (FGFR3) gene are frequently found in bladder cancer, but their prognostic value remains controversial. To globally summarize the association between FGFR3 mutations and the grade and stage of bladder cancer, and to analyze the predictive role of FGFR3 mutations with respect to survival, eligible studies were identified and assessed for quality through multiple search strategies. Risk ratio (RR) data were collected from studies comparing the number of FGFR3 mutants among low-grade and early-stage bladder cancer patients to the number among high-grade and late-stage patients. Hazard ratio (HR) data were collected from studies comparing survival in patients with mutant FGFR3 genes to those with wild-type genes. Studies were pooled, and the RRs of grade and stage and the HRs of survival were
An amperometric detector based on the chemical modification of Nafion and indium (III) hexacyanoferrate (II, III) thin film (Nafion/In-CN-Fe) onto a glassy carbon (GC) electrode, was first successfully used for the determination of electroinactive cations (Li+, Na+, K+, Rb+, Cs+, NH4+) in single column ion chromatography (IC). A set of well-defined peaks of electroinactive cations was obtained. The detection limits of the cations are 8.9 x 10(-6) mol/L for Li+, 2.3 x 10(-6) mol/L for Na+, 5.2 x 10(-6) mol/L for K+, 4.8 x 10(-6) mol/L for Rb+, 4.0 x 10(-6) mol/L for Cs+ and 5.3 x 10(-6) mol/L for NH4+ at a single-to-noise ratio of 3. The proposed method was quick, sensitive and simple. The cations in rainwater and mineral water were successfully analyzed by this method.
SummaryA simple, selective and sensitive ion-chromatography method was investigated for simultaneously determining silicic acid, Ca 2+, Mg 2+, AI 3+ and anions (CI-and NO3-)in real samples. It involved a single-column ion-chromatograph with sodium hydroxide-methanol-water eluent and concluctometric detection. Cations were converted to complex anions by adding EDTA to the sample solution. A set of well-defined peaks of silicic acid, Ca 2+, Mg 2+, AI 3+, CI-and NO3-were obtained. Detection limits using 3.3c~ (c~ = standard deviation of blank solution) were 1.25 x 10 -6 M for H3SiO4-,
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.