This paper presents a fully integrated photodiode-based low-power and low-mismatch stimulator for a subretinal prosthesis. It is known that a subretinal prosthesis achieves 1600-pixel stimulators on a limited single-chip area that is implanted beneath the bipolar cell layer. However, the high-density pixels cause high power dissipation during stimulation and high fabrication costs because of special process technologies such as the complementary metal-oxide semiconductor CMOS image sensor process. In addition, the many residual charges arising from the high-density pixel stimulation have deleterious effects, such as tissue damage and electrode corrosion, on the retina tissue. In this work, we adopted a switched-capacitor current mirror technique for the single-pixel stimulator (SPStim) that enables low power consumption and low mismatch in the subretinal device. The customized P+/N-well photodiode used to sense the incident light in the SPStim also reduces the fabrication cost. The 64-pixel stimulators are fabricated in a standard 0.35-μm CMOS process along with a global digital controller, which occupies a chip area of 4.3 × 3.2 mm2 and are ex-vivo demonstrated using a dissected pig eyeball. According to measured results, the SPStim accomplishes a maximum biphasic pulse amplitude of 143 μA, which dissipates an average power of 167 μW in a stimulation period of 5 ms, and an average mismatch of 1.12 % between the cathodic and anodic pulses.
The robustness of the reference circuit in a wide range of supply voltages is crucial in implanted devices. Conventional reference circuits have demonstrated a weak performance over wide supply ranges. Channel-length modulation in the transistors causes the circuit to be sensitive to power supply variation. To solve this inherent problem, this paper proposes a new output-voltage-line-regulation controller circuit. When a variation occurs in the power supply, the controller promptly responds to the supply deviation and removes unwanted current in the output path of the reference circuit. The proposed circuit was implemented in a 0.35-μm SK Hynix CMOS standard process. The experimental results demonstrated that the proposed reference circuit could generate a reference voltage of 0.895 V under a power supply voltage of 3.3 V, line regulation of 1.85 mV/V in the supply range of 2.3 to 5 V, maximum power supply rejection ratio (PSRR) of −54 dB, and temperature coefficient of 11.9 ppm/°C in the temperature range of 25 to 100 °C.
Significant progress has been made in the field of micro/nano-retinal implant technologies. However, the high pixel range, power leakage, reliability, and lifespan of retinal implants are still questionable. Active implantable devices are safe, cost-effective, and reliable. Although a device that can meet basic safety requirements set by the Food and Drug Administration and the European Union is reliable for long-term use and provides control on current and voltage parameters, it will be expensive and cannot be commercially successful. This study proposes an economical, fully controllable, and configurable wireless communication system based on field-programmable gated arrays (FPGAs) that were designed with the ability to cope with the issues that arise in retinal implantation. This system incorporates hexagonal biphasic stimulation pulses generated by a digital controller that can be fully controlled using an external transmitter. The integration of two separate domain analog systems and a digital controller based on FPGAs is proposed in this study. The system was also implemented on a microchip and verified using in vitro results.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.