Power loss and voltage instability are major problems in distribution systems. However, these problems are typically mitigated by efficient network reconfiguration, including the integration of distributed generation (DG) units in the distribution network. In this regard, the optimal placement and sizing of DGs are crucial. Otherwise, the network performance will be degraded. This study is conducted to optimally locate and sizing of DGs into a radial distribution network before and after reconfiguration. A multi-objective particle swarm optimization algorithm is utilized to determine the optimal placement and sizing of the DGs before and after reconfiguration of the radial network. An optimal network configuration with DG coordination in an active distribution network overcomes power losses, uplifts voltage profiles, and improves the system stability, reliability, and efficiency. For considering the actual power system scenarios, a penalty factor is also considered, this penalty factor plays a crucial role in the minimization of total power loss and voltage profile enhancement. The simulation results showed a significant improvement in the percentage power loss reduction (32% and 68.05% before and after reconfiguration, respectively) with the inclusion of DG units in the test system. Similarly, the minimum bus voltage of the system is improved by 4.9% and 6.53% before and after reconfiguration, respectively. The comparative study is performed, and the results showed the effectiveness of the proposed method in reducing the voltage deviation and power loss of the distribution system. The proposed algorithm is evaluated on the IEEE-33 bus radial distribution system, using MATLAB software.
The performance of a typical solar energy-based system can be improved by accurately modeling the current versus voltage characteristics of the involved solar cells. However, estimating the exact value of parameters related to solar cells is quite challenging. The optimization function, considering the current–voltage characteristics of solar cells, requires the solution of sophisticated non-linear and multi-modal optimization methods. So far, various optimization approaches have been reported. This paper proposes the application of a new hybrid algorithm, i.e., Particle Swarm Optimization and Gravitational Search Algorithm (PSOGSA), which is a combination of two algorithms, i.e., Gravitational Search Algorithm (GSA) and Particle Swarm Optimization (PSO) method. The hybrid PSOGSA algorithm is superior to other algorithms in terms of higher accuracy in searching for optimal solutions and better explorative capability. Moreover, the developed hybrid algorithm is benchmarked using ten standard test functions to verify its efficiency. In this manuscript, monocrystalline and polycrystalline solar cells are considered. The parameter optimization results are obtained using PSOGSA and further compared with those obtained using other algorithms presented in the literature, such as PSO, GSA, MVO, HBO, PO and SCA. The complete error analysis is carried out for the modified single-diode model (MSDM), the modified double-diode model (MDDM), and the modified three-diode model (MTDM) of photovoltaic (PV) cells to prove the superiority of the PSOGSA. Moreover, statistical results are carried out based on Friedman’s ranking and Wilcoxon’s rank sum test. The comparison results show that the proposed PSOGSA is better than other algorithms in estimating the unknown PV model parameters.
Seismic design of structures taking into account the soil-structure interaction (SSI) methods is considered to be more efficient, cost effective, and safer then fixed-base designs, in most cases. Finite element methods that use direct equations to solve SSI problems are very popular, but the prices of the software are very high, and the analysis time is very long. Even though some low-cost and efficient software are available, the structures are mostly analyzed for the superstructure only, without using the geotechnical properties of the ground and its interaction effects. The reason is that a limited number of researchers have the knowledge of both geotechnical and structural engineering to model accurately the coupled soil-structure system. However, a cost-effective, less time-consuming and easy-to-implement technique is to analyze the structure along with ground properties using machine learning methods. The database techniques using machine learning are robust and provide reliable results. Thus, in this study, machine learning techniques, such as artificial neural networks and support vector machines are used to investigate the effect of soil-structure interactions on the seismic response of structures for different earthquake scenarios. Four frame structures are investigated by varying the soil and seismic properties. In addition, varying sample sizes and different optimization algorithms are used to obtain the best machine learning framework. The input parameters contain both soil and seismic properties, while the outputs consist of three engineering demand parameters. The network is trained using three and five-story buildings and tested on a three-story building with mass irregularity and a four-story building. Furthermore, the proposed method is compared with the dynamic responses obtained using fixed-base and ASCE 7-16 SSI methods. The proposed machine learning method showed better results compared with fixed-base and ASCE 7-16 methods with the nonlinear time history analysis results as a reference.
With the emergence of the smart grid, the distribution network is facing various problems, such as power limitations, voltage uncertainty, and many others. Apart from the power sector, the growth of electric vehicles (EVs) is leading to a rising power demand. These problems can potentially lead to blackouts. This paper presents three meta-heuristic techniques: grey wolf optimization (GWO), whale optimization algorithm (WOA), and dandelion optimizer (DO) for optimal allocation (sitting and sizing) of solar photovoltaic (SPV), wind turbine generation (WTG), and electric vehicle charging stations (EVCSs). The aim of implementing these techniques is to optimize allocation of renewable energy distributed generation (RE-DG) for reducing active power losses, reactive power losses, and total voltage deviation, and to improve the voltage stability index in radial distribution networks (RDNs). MATLAB 2022a was used for the simulation of meta-heuristic techniques. The proposed techniques were implemented on IEEE 33-bus RDN for optimal allocation of RE-DGs and EVCSs while considering seasonal variations and uncertainty modeling. The results validate the efficiency of meta-heuristic techniques with a substantial reduction in active power loss, reactive power loss, and an improvement in the voltage profile with optimal allocation across all considered scenarios.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.