In this paper, the ultimate load capacities of shell foundations on unreinforced and reinforced sand were determined by laboratory model tests. A series of loading tests were carried out on model shell footing with and without single layer of reinforcement. The tests were done for shell foundation at different shell embedment depth and subgrade density. The results were compared with those for flat foundations without reinforcement. The model test results were verified using finite element analysis using program PLAXIS. The experimental studies indicated that, the ultimate load capacity of shell footing on reinforced subgrade is higher than those on unreinforced cases and the load settlement curves were significantly modified. The shell foundation over reinforced subgrade can be considered a good method to increase the effective depth of the foundation and decrease the resulting settlement. Also the rupture surface of shell reinforced system was significantly deeper than both normal footing and shell footing without reinforcement. The numerical analysis helps in understanding the deformation behavior of the studied systems and identifies the failure surface of reinforced shell footing.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.