A magnetically levitated centrifugal blood pump (MedTech Dispo) has been developed for use in a disposable extracorporeal system. The design of the pump is intended to eliminate mechanical contact with the impeller, to facilitate a simple disposable mechanism, and to reduce the blood-heating effects that are caused by motors and magnetic bearings. The bearing rotor attached to the impeller is suspended by a two degrees-of-freedom controlled radial magnetic bearing stator, which is situated outside the rotor. In the space inside the ringlike rotor, a magnetic coupling disk is placed to rotate the rotor and to ensure that the pump head is thermally isolated from the motor. In this system, the rotor can exhibit high passive stiffness due to the novel design of the closed magnetic circuits. The disposable pump head, which has a priming volume of 23 mL, consists of top and bottom housings, an impeller, and a rotor with a diameter of 50 mm. The pump can provide a head pressure of more than 300 mm Hg against a flow of 5 L/min. The normalized index of hemolysis of the MedTech Dispo is 0.0025 +/- 0.0005 g/100 L at 5 L/min against 250 mm Hg. This is one-seventh of the equivalent figure for a Bio Pump BPX-80 (Medtronic, Inc., Minneapolis, MN, USA), which has a value of 0.0170 +/- 0.0096 g/100 L. These results show that the MedTech Dispo offers high pumping performance and low blood trauma.
Controlling the flow rate in an implantable rotary blood pump based on the physiological demand made by the body is important. Even though various methods to estimate the flow rate without using a flow meter have been proposed, no adequate method for measuring the blood viscosity, which is necessary for an accurate estimate of the flow rate, without using additional sensors or mechanisms in a noninvasive way, has yet been realized. We have developed a sensorless method for measuring viscosity in magnetically levitated rotary blood pumps, which requires no additional sensors or mechanisms. By applying vibrational excitation to the impeller using a magnetic bearing, we measured the viscosity of the working fluid by measuring the phase difference between the current in the magnetic bearing and the displacement of the impeller. The measured viscosity showed a high correlation (R(2) > 0.992) with respect to a reference viscosity. The mean absolute deviation of the measured viscosity was 0.12 mPa·s for several working fluids with viscosities ranging from 1.18 to 5.12 mPa·s. The proposed sensorless measurement method has the possibility of being utilized for estimating flow rate.
MedTech Dispo, a disposable maglev centrifugal blood pump with two degrees of freedom magnetic suspension and radial magnetic coupling rotation, has been developed for 1-month extracorporeal circulatory support. As the first stage of a two-stage in vivo evaluation, 2-week evaluation of a prototype MedTech Dispo was conducted. In in vitro study, the pump could produce 5 L/min against 800 mm Hg and the normalized index of hemolysis was 0.0054 +/- 0.0008 g/100 L. In in vivo study, the pump, with its blood-contacting surface coated with biocompatible 2-methacryloyloxyethyl phosphorylcholine polymer, was implanted in seven calves in left heart bypass. Pump performance was stable with a mean flow of 4.49 +/- 0.38 L/min at a mean speed of 2072.1 +/- 64.5 rpm. The maglev control revealed its stability in rotor position during normal activity by the calves. During 2 weeks of operation in two calves which survived the intended study period, no thrombus formation was seen inside the pump and levels of plasma free hemoglobin were maintained below 4 mg/dL. Although further experiments are required, the pump demonstrated the potential for sufficient and reliable performance and biocompatibility in meeting the requirements for cardiopulmonary bypass and 1-week circulatory support.
Mechanical shaft seal bearing incorporated in the centrifugal blood pumps contributes to hemolysis and thrombus formation. In addition, the problem of durability and corrosion of mechanical shaft seal bearing has been recently reported from the safety point of view. To amend the shortcomings of the blood-immersed mechanical bearings, a magnetic levitated centrifugal rotary blood pump (MedTech Dispo Model 1; Tokyo Medical and Dental University, Tokyo, Japan) has been developed for extracorporeal disposable application. In this study, the hemolytic performance of the MedTech Dispo Model 1 centrifugal blood pump system was evaluated, with special focus on the narrow blood path clearance at the magnetic bearing between rotor and stator, and on the pump housing surface roughness. A pump flow of 5 L/min against the head pressure of 100 mm Hg for 4 h was included in the hemolytic test conditions. Anticoagulated fresh porcine blood was used as a working fluid. The clearance of blood path at the magnetic bearing was in the range of 100-250 micro m. Pump housing surface roughness was controlled to be around Ra = 0.1-1.5 micro m. The lowest hemolytic results were obtained at the clearance of 250 micro m and with the polished surface (Ra = 0.1 micro m) yielding the normalized index of hemolysis (NIH) of less than 0.001 g/100 L, which was 1/5 of the Biopump BP-80 (Medtronic Inc., Minneapolis, MN, USA, and 1/4 of the BPX-80. In spite of rough surface and narrow blood path, NIH levels were less than clinically acceptable level of 0.005 g/100 L. The noncontact, levitated impeller system is useful to improve pump performance in blood environment.
Ventricular assist devices assist in blood circulation and form a crucial component of artificial hearts. While it is important to measure parameters such as the flow rate, pressure head and viscosity of the blood, implanting additional devices to do such measurements is inadvisable. To this end, we demonstrate the adaptation of a ventricular assist device for the purpose of measuring blood viscosity. Such an approach eliminates the need for additional dedicated viscometers in artificial hearts. In the proposed method, the blood viscosity is measured by applying radial vibrational excitation to the impeller in a ventricular assist device using its magnetic levitation system. During the measurement, blood is exposed to a combination of a low shear rate (≈100/s) generated by the radial vibration of the impeller and a high shear rate (>10,000/s) generated by the impeller’s rotation. The apparent viscosity of blood depends on the shear rate, so we determined which shear rate was the dominant one in the proposed method. The measurement results showed that the viscosity measured by the proposed method was in good agreement with the reference viscosity measured with a high shear rate. The mean absolute deviation in the measurements using the proposed method and those obtained using a concentric cylindrical viscometer at a high shear rate was 0.12 mPa s for four samples of porcine blood, with viscosities ranging from 2.32 to 2.75 mPa s.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.