Liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis of the tryptic digest of a cleaned-up food matrix extract was used for the detection of milk allergens. The emphasis of this study was on casein, which is the most abundant milk protein and is also considered the most allergenic. A sample cleanup method was developed using an ion exchange column and centriprep device. Cookies spiked with milk powder from 0 to 1250 ppm were extracted, cleaned up, and either digested directly by trypsin or further cleaned up by gel electrophoresis before digestion. The peptide mixture was analyzed on a capillary LC-quadrupole time-of-flight system. Two marker peptides from alphaS1-casein were identified and used for prescreening. The MS/MS data from the mass spectrometry system were processed with Masslynx v4.0 and submitted for database search using either ProteinLynx Global Server or Mascot for protein identification. The LC-MS/MS method, using casein enzyme-linked immunosorbent assay as a reference, was tested on the cookie matrix and was extended to other sample matrices. There were good agreements between the two. This LC-MS/MS method provides a valuable confirmatory method for the presence of casein. It also allows the simultaneous detection of other milk allergens.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.