The large net torque fluctuations in the reducer output shafts of conventional beam pumping units and the existence of negative torque are the decisive factors that lead to their low efficiency and high energy consumption. This study developed a positive torque modulation scheme for conventional beam pumping units, which was based on the principle of the follow-up secondary balance of the connecting rod. The CYJ10-4.2-53HF conventional beam pumping unit was selected as the research object. The kinematic and dynamic simulation analysis of the modified pumping unit was carried out using ADAMS software. The results showed that secondary balance torque curves could realize the function of “peak cutting and valley filling” for the curves after the primary balance and that the modified pumping unit could achieve a full-cycle positive value for the reducer output shaft and verify the feasibility of our modulation scheme. A secondary balance offset angle of 315° was the best choice as the amplitude of the torque curve clearly increased and the phase remained basically the same when the radius of the mass center of the secondary balance increased. Therefore, when the offset angle value of the secondary balance weight was determined, the radius of the mass center could be changed by adjusting the position of the secondary balance weight to achieve the balance adjustment.
The large fluctuation of net torque and the existence of negative torque on the crank output shaft of the beam pumping unit are the decisive factors leading to its low efficiency and high energy consumption. The conventional pumping unit CYJ10-4.2-53HF was selected as the study object on the basis of the fixed shaft secondary balance principle and the positive torque modulation scheme was first proposed according to the following secondary balance principle based on the linkage. The kinematics analysis of the suspension point and the secondary incremental velocity mechanism were carried out using the theory of rigid body plane kinematics. The force analysis of each moving part of the pumping unit was carried out, the net torque expression of the crank output shaft was obtained, and an example calculation was performed. The positive torque beam pumping unit was developed and tested in a field test. The tests showed that the positive torque beam pumping unit was able to fully realize positive torque operation under field well conditions, with a power saving rate of 23.73% and a 14.5% increase in system efficiency, and that the reliability of the pumping unit meets the requirements for field application.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.