The present study intends to develop building-integrated solar collector (BISC). The storage tank inside is designed in multi-function. BISC combines the solar collector and the water storage tank together with one face acting as the solar absorber. A double-glazing design is adopted to reduce the heat loss. A PC-based automatic operating system is designed and built to monitor the long-term performance of the BISC system with 8 collector units. Hot water discharge is controlled from 18:00 until 22:00 to simulate the hot water load of a family. The discharge rate is at 60 L/hr. A 30 L backup electric water heater was connected to the BISC system. The long-term test results in winter season show that about 50 % energy saving was achieved in clear days. The monitored results have also shown that the daily-total solar irradiation on a 75 o tilted surface (the BISC installed angle) is higher than the horizontal surface, about 40-50 % higher at Ht > 10 MJ/m^2day. This assures that BISC will produce more hot water in winter. This proves that the use of BISC as parapet or sun-shading canopy of a building (installation angle > 75 o) is technically feasible. The characteristic efficiency of the installed BISC with different colors is 0.34-0.39.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.