Purpose: The aim of this project is to investigate the usefulness of the absolute liver lesion ADC value and ratio of Apparent diffusion coefficient (ADC) values of a liver lesion and liver parenchyma to discriminate between a benign and malignant lesion.Methods: Liver MRI scans performed between January 2009 and June 2015 were retrospectively analysed. Scans were performed on either a 1.5 T or 3 T MRI unit. The type of liver lesion (benign or malignant) was determined by its radiological appearance, histology result and clinical management. Lesions with undetermined diagnosis or MRI studies degraded by artifacts were excluded. Liver cysts were also excluded from the analysis. ADC value of a lesion and liver parenchyma was measured and ADCratio was calculated. The values were analysed using independent samples t-testResults:Data set contained 39 benign lesions and 36 malignant lesions. Mean ADC value for benign lesions was 1678, and the mean value for malignant lesions was 1097 with a statistically significant difference of p < 0.001. All lesions with ADC value below 955 were malignant, while all lesions with ADC value above 1880 were benign. ADC value of 1260 was identified as the best available cut-off value for differentiating benign and malignant lesions, achieving sensitivity of 92%, specificity of 80% and an overall accuracy of 89%. The mean lesion to liver ADCratio for benign lesions was 1.3467 and for malignant lesions was 0.9038 with a statistically significant difference of p < 0.001. All lesions with ADCratio measuring <0.9 were malignant while lesions with ADCratio>1.5 were benign. ADCratio of 1.1 was identified statistically as the best available cut-off value for differentiating benign from malignant lesions, with sensitivity of 82%, specificity of 86% and an overall accuracy of 92%.Conclusion:Our dataset indicates that lesion to background liver ADCratio is superior in discriminating between benign and malignant focal lesions compared to absolute ADC values of the hepatic lesions.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.