BACKGROUND The recent identification of a novel coronavirus, also known as SARS-CoV-2, has caused a global outbreak of respiratory illnesses. The rapidly developing pandemic has posed great challenges to diagnosis of this novel infection. However, little is known about the metatranscriptomic characteristics of patients with Coronavirus Disease 2019 (COVID-19). METHODS We analyzed metatranscriptomics in 187 patients (62 cases with COVID-19 and 125 with non-COVID-19 pneumonia). Transcriptional aspects of three core elements – pathogens, the microbiome, and host responses – were interrogated. Based on the host transcriptional signature, we built a host gene classifier and examined its potential for diagnosing COVID-19 and indicating disease severity. RESULTS The airway microbiome in COVID-19 patients had reduced alpha diversity, with 18 taxa of differential abundance. Potentially pathogenic microbes were also detected in 47% of the COVID-19 cases, 58% of which were respiratory viruses. Host gene analysis revealed a transcriptional signature of 36 differentially expressed genes significantly associated with immune pathways such as cytokine signaling. The host gene classifier built on such a signature exhibited potential for diagnosing COVID-19 (AUC of 0.75-0.89) and indicating disease severity. CONCLUSIONS Compared to those with non-COVID-19 pneumonias, COVID-19 patients appeared to have a more disrupted airway microbiome with frequent potential concurrent infections, and a special trigger host immune response in certain pathways such as interferon gamma signaling. The immune-associated host transcriptional signatures of COVID-19 hold promise as a tool for improving COVID-19 diagnosis and indicating disease severity.
The modeling of superconducting magnetic bearing (SMB) is of great significance for predicting and optimizing its levitation performance before construction. Although lots of efforts have been made in this area, it still remains some space for improvements. Thus the goal of this work is to report a flexible, fast and trustworthy H-formulation finite element model. First the methodology for modeling and calibrating both bulk-type and stack-type SMB is summarized. Then its effectiveness for simulating SMBs in 2-D, 2-D axisymmetric and 3-D is evaluated by comparison with measurements. In particular, original solutions to overcome several obstacles are given: clarification of the calibration procedure for stack-type and bulk-type SMBs, details on the experimental protocol to obtain reproducible measurements, validation of the 2-D model for a stack-type SMB modeling the tapes real thickness, implementation of a 2-D axisymmetric SMB model, implementation of a 3-D SMB model, extensive validation of the models by comparison with experimental results for field cooling and zero field cooling, for both vertical and lateral movements. The accuracy of the model being proved, it has now a strong potential for speeding up the development of numerous applications including maglev vehicles, magnetic launchers, flywheel energy storage systems, motor bearings and cosmic microwave background polarimeters.
Three superconducting stacks made of 120 REBCO coated conductor tapes were each fabricated and assembled to obtain several REBCO modules. Their levitation responses over two different permanent magnet (PM) guideways were investigated by experiment and finite element simulation. For the experiment, a test rig was developed that can measure the force in the three directions for any given relative movement between the REBCO stacks and the PM guideway. For the finite element simulation, a 2D H-formulation was adopted. To treat the high aspect ratio of REBCO tapes, an anisotropic homogenization technique was used. The agreement between the measurements and the simulations is good, thus validating the modeling methodology. It was observed from the experiment and simulation results that the perpendicular field contributes to the levitation force whereas the parallel field is responsible for the guidance force, as a result of the existence of anisotropy on the local magnetic stimulation. Based on that, promising REBCO modules including both longitudinal and transverse arrangements of REBCO stacks were proposed and tested, in terms of providing a significant levitation force with the lateral stability preserved. Moreover, a pre-load process able to suppress the relaxation of the levitation force was put forward. To conclude, this study outlines explicit principles to obtain an appropriate layout of coated conductor stacks that could be effective for practical magnetic levitation operation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.