Background:The concept of the involvement of systemic inflammation in cancer progression and metastases has gained attraction within the past decade. C-reactive protein (CRP), a non-specific blood-based marker of the systemic inflammatory response, has been associated with decreased survival in several cancer types. The aim of the present study was to validate the prognostic value of pre-operative plasma CRP levels on clinical outcome in a large cohort of soft-tissue sarcoma (STS) patients.Methods:Three hundred and four STS patients, operated between 1998 and 2010, were retrospectively evaluated. CRP levels and the impact on cancer-specific survival (CSS), disease-free survival (DFS) and overall survival (OS) were assessed using Kaplan–Meier curves and univariate as well as multivariate Cox proportional models. Additionally, we developed a nomogram by supplementing the plasma CRP level to the well-established Kattan nomogram and evaluated the improvement of predictive accuracy of this novel nomogram by applying calibration and Harrell's concordance index (c-index).Results:An elevated plasma CRP level was significantly associated with established prognostic factors, including age, tumour grade, size and depth (P<0.05). In multivariate analysis, increased CRP levels were significantly associated with a poor outcome for CSS (HR=2.05; 95% CI=1.13–3.74; P=0.019) and DFS (HR=1.88; 95% CI=1.07–3.34; P=0.029). The estimated c-index was 0.74 using the original Kattan nomogram and 0.77 when the plasma CRP level was added.Conclusion:An elevated pre-operative CRP level represents an independent prognostic factor that predicts poor prognosis and improves the predictive ability of the Kattan nomogram in STS patients. Our data suggest to further prospectively validate its potential utility for individual risk stratification and clinical management of STS patients.
Reconstruction with massive bone allograft and autologous vascularised fibula combines the structural strength of the allograft and the advantages of fibula's intrinsic blood supply. We retrospectively analysed the outcome of twelve patients (4 male, 8 female) who received reconstruction with massive bone allograft and autologous vascularised fibula after tumour resection in lower limb. Mean age was 17.8 years (range 11–31 years), with following primaries: Ewing's sarcoma (n = 6), osteosarcoma (n = 4), liposarcoma grade 2 (n = 1), and adamantinoma (n = 1). Mean followup was 38.7 months (median 25.7 months; range 2–88 months). Seven tumours were located in the femur and five in the tibia. The mean length of bone defect was 18.7 cm (range 15–25 cm). None of the grafts had to be removed, but there occurred four fractures, four nonunions, and two infections. Two patients developed donor side complication, in form of flexion deformity of the big toe. The event-free survival rate was 51% at two-year followup and 39% at three- and five-year followup. As the complications were manageable, and full weight bearing was achieved in all cases, we consider the combination of massive bone allograft and autologous vascularised fibula a stable and durable reconstruction method of the diaphysis of the lower limbs.
Introduction Preoperative planning is an essential part of total hip arthroplasty (THA). It facilitates the surgical procedure, helps to provide the correct implant size and aims at restoring biomechanical conditions. In recent times, surgeons rely more and more on digital templating techniques. Although the conversion to picture archiving and communication system had many positive effects, there are still problems that have to be taken into consideration. Objectives The core objective was to evaluate the impact of the planners’ experience on the accuracy of predicting component size in digital preoperative templating of THA. In addition, the influence of overweight and obesity (according to WHO-criteria), patient’s sex and component design on the accuracy of preoperative planning have been analysed. Materials and methods The retrospective study included 632 consecutive patients who had primary uncemented THA. Digital templating was done using “syngo—EndoMap” software by Siemens Medical Solutions AG. Mann–Whitney U test and Kruskal–Wallis test have been used for statistical analysis. The accuracy of predicting component size has been evaluated by comparing preoperative planned sizes with implanted sizes as documented by the surgeons. The planner’s experience was tested by comparing the reliability of preoperative planning done by senior surgeons or residents. The influence of BMI on predicting component size has been tested by comparing the accuracy of digital templating between different groups of BMI according to WHO-criteria. The same procedure has been done for evaluating the impact of patient´s sex and component design. Results The implant size was predicted exactly in 42% for the femoral and in 37% for the acetabular component. 87% of the femoral components and 78% of the acetabular cups were accurate within one size. Digital templating of femoral implant size was significantly more reliable when done by a senior surgeon. No difference was found for the acetabular component sizes. The BMI also had an impact on estimating the correct femoral implant size. In overweight patients, planning was significantly more inaccurate than normal weight people. Differences were seen in obese patients. However, these were not significant. Accuracy of acetabular components was not affected. The design of the prostheses and the patient’s sex had no influence on predicting component size. Conclusions Inexperience and overweight are factors that correlate with inaccuracy of preoperative digital templating in femoral components, whereas acetabular components seem to be independent of these factors.
The English version of the online encyclopedia, Wikipedia, has been recently reported to be the prominent source of online health information. However, there is little information concerning the quality of information found in Wikipedia. Therefore, we created a questionnaire asking for scope, completeness, and accuracy of information found on osteosarcoma. Three independent observers tested the English version of Wikipedia, as well as the patient version and the health professional version of the US National Cancer Institute (NCI) website. Answers were verified with authoritative resources and international guidelines. The results of our study demonstrate that the quality of osteosarcomarelated information found in the English Wikipedia is good but inferior to the patient information provided by the NCI. Therefore, non-peer-reviewed commonly used websites offering health information, such as Wikipedia, should include links to more definitive sources, such as those maintained by the NCI and professional international organizations on healthcare treatments. Furthermore, frequent checks should make sure such external links are to the highest quality and to the bestmaintained aggregate sites on a given healthcare topic.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.