Extracorporeal membrane oxygenation (ECMO) is a lifesaving therapy, which has been used for the support of children with a broad range of diseases. Two pumps of differing mechanisms have been used to generate the extracorporeal flow: roller-head pumps and centrifugal pumps. Seven patients supported during ECMO with Levitronix Centrimag (Centrimag group [CG]) were matched to 14 patients supported with Stockert-Shiley SIII (Stockert-Shiley group [SSG]) at a single institution from July 2007 to July 2009. We hypothesized that hemolysis as measured by plasma-free hemoglobin (PFH) is elevated in the SSG versus the CG during cardiac ECMO. Categorical data were analyzed using Fisher's exact test. Plasma-free hemoglobin differences between groups were analyzed using both Wilcoxon rank sum and beta regression. Overall, SSG patients had two times the odds of having a higher PFH than CG patients adjusting for repeated measures (odds ratio [OR] = 1.96, 95% confidence interval [CI]: [1.15-3.34], p < 0.014). Differences between circuit failure in the first 168 hours did not reach statistical significance (1/7 CG vs. 7/14 SSG; p = 0.174). In this population of cardiac patients requiring ECMO support, more hemolysis occurred in the SSG, a roller-head pump supported group, when compared with the CG, a centrifugal pump supported group. Differences in circuit life did not reach statistical significance. This pilot study contrasts with past studies, which have demonstrated more hemolysis occurring with centrifugal pumps when compared with roller-head pumps.
Patients supported with extracorporeal membrane oxygenation were exposed to large RBC transfusion volumes for treatment of mild anemia resulting from blood loss, particularly phlebotomy. In the majority of events, RBC transfusion did not significantly alter global tissue oxygenation, as assessed by changes in SvO2 and cerebral near-infrared spectroscopy. Most transfusions were administered at a time at which the patient did not appear to be oxygen delivery dependent according to global measures of tissue oxygenation.
Patients undergoing extracorporeal membrane oxygenation (ECMO) are at increased risk of infection. We present the first known report of nosocomial infection with Cupriavidus pauculus attributable to contamination from ECMO equipment and describe the measures taken to halt subsequent infections. A cluster of infections in ECMO patients should prompt team members to consider contamination of equipment with environmental pathogens as a possible cause.
Embolization of marrow fat appears to be an inevitable consequence of long bone fractures. Pulmonary fat embolism (FE) with cardiovascular collapse is associated with a high mortality rate because of acute right ventricular failure and hypoxia. Immediate and appropriate resuscitation is required to prevent sudden death. Although extracorporeal membrane oxygenation (ECMO) has been used for a multitude of applications involving respiratory and circulatory collapse, its full potential as a standard conventional therapy has yet to be exploited. Herein, we describe the successful use of veno-venous (V-V) ECMO in a trauma patient who initially presented with fractures of the right ulna and femur. After surgery, the patient rapidly decompensated despite massive ventilatory support and was placed on ECMO. ECMO support lasted approximately 120 hours followed by an uneventful recovery and discharge 10 days later.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.