The methodological quality and the quality of reporting of the studies were highly variable. With respect to range of motion, pain, clinical, and radiological outcomes, no clinically relevant differences were found between total knee arthroplasty with retention or sacrifice of the posterior cruciate ligament. Two statistically significant differences were found; range of motion was 2.4 ° higher in the posterior cruciate ligament sacrificing group, however results were heterogeneous; and the mean functional Knee Society Score was 2.3 points higher in the posterior cruciate ligament sacrificing group. These differences are clinically not relevant.
Background Less than 1% of all primary TKAs are performed with an all-polyethylene tibial component, although recent studies indicate all-polyethylene tibial components are equal to or better than metal-backed ones. Questions/purposes We asked whether the metal-backed tibial component was clinically superior to the all-polyethylene tibial component in primary TKAs regarding revision rates and clinical functioning, and which modifying variables affected the revision rate.Methods We systematically reviewed the literature for clinical studies comparing all-polyethylene and metalbacked tibial components used in primary TKAs in terms of revision rates, clinical scores, and radiologic parameters including radiostereometric analysis (RSA). Meta-regression techniques were used to explore factors modifying the observed effect. Our search yielded 1557 unique references of which 26 articles were included, comprising more than 12,500 TKAs with 231 revisions for any reason. Results Meta-analysis showed no differences between the all-polyethylene and metal-backed components except for higher migration of the metal-backed components. Metaregression showed strong evidence that the all-polyethylene design has improved with time compared with the metalbacked design. Conclusions The all-polyethylene components were equivalent to metal-backed components regarding revision rates and clinical scores. The all-polyethylene components had better fixation (RSA) than the metal-backed components. The belief that metal-backed components are better than all-polyethylene ones seems to be based on studies from earlier TKAs. This might no longer be true for modern TKAs. Level of Evidence Level II, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.
Background and purpose To retain or to sacrifice the posterior cruciate ligament (PCL) in total knee arthroplasty (TKA) remains a matter of discussion. In this systematic review, we wanted to find differences in functional and clinical outcome between the 2 methods.Methods We conducted a systematic review and meta-analysis including all randomized controlled trials (RCTs) and quasi-RCTs that have compared PCL retention with PCL sacrifice in TKA with a minimum of 1-year follow-up. Primary outcome was range of motion. Secondary outcomes were knee pain and clinical scoring systems that were preferably validated. Quality of evidence was graded using the GRADE approach. All outcomes available for data pooling were used for meta-analysis.Results 20 studies involving 1,877 patients and 2,347 knees were included. In meta-analysis, the postoperative flexion angle had a mean difference of 2 degrees (95% CI: 0.23–4.0; p = 0.03) and the KSS functional score was 2.4 points higher in favor of PCL sacrifice (95% CI: 0.41–4.3; p = 0.02). There were no statistically significant differences regarding other measured clinical outcomes such as WOMAC, KSS pain, clinical and overall score, HSS score, SF-12, radiolucencies, femoro-tibial angle, and tibial slope. The quality of the studies varied considerably. Risk of bias in most studies was unclear; 5 were judged to have a low risk of bias and 5 to have a high risk of bias.Interpretation We found no clinically relevant differences between retention and sacrifice of the PCL in TKA, in terms of functional and clinical outcomes. The quality of the studies ranged from moderate to low. Based on the current evidence, no recommendation can be made as to whether to retain or to sacrifice the PCL.
In patients with a short onset of neurologic impairment because of compression of the spinal cord or caudal fibers, an intraoperative recovery of transcranial electrical stimulation motor evoked potentials can indicate an improvement of motor function postoperatively. Therefore, transcranial electrical stimulation motor evoked potentials can be considered as a useful tool to the surgeon to monitor the quality of decompression of the spinal cord.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.