Peak Flow Meter (PFM) is a tool to measure the amount of air flow in the airway (PFR) and to detect asthma. The output value of PFR can be influenced by several factors, such as age, respiratory muscle strength, height and gender. In this research, airway measurements are used to measure the condition of patients suffering from asthma. The author aims to make this tool so that it can find out how to design and make a peak flow meter output sound tool, measure the peak current and can know how the MPXV7002DP sensor works in regulating output in the form of sound. The method used by the author is to design or make a tool peak flow meter output sound. This MPXV7002DP sensor works when the sensor receives air blows from the flow sensor which automatically reads the highest air pressure from the breath. The test results using the VT Mobile Medical Gas Flow Analyzer prove that the largest percentage error is 2.4%, with the blowing rate on the Peak Flow Meter is 64.0 lpm and the blowing rate on VT mobile is 62.50 lpm. Therefore, this tool can be said to be very certain to detect asthma. Then it can be concluded that the peak flow meter is feasible and meets the specified requirements.Peak Flow Meter (PFM) is a tool to measure the amount of air flow in the airway (PFR) and to detect asthma. The value of PFR can be influenced by several factors such as age, respiratory muscle strength, height and gender. Airway measurements are used to measure the condition of patients suffering from asthma. The author aims to make this tool so that it can find out how to design and make a peak flow meter output sound tool, measure the peak current and can know how the MPXV7002DP sensor works in regulating output in the form of sound. The method used by the author is to design or make a tool peak flow meter output sound. This MPXV7002DP sensor works when the sensor receives air blows from the flow sensor which automatically reads the highest air pressure from the breath. The test results using the VT Mobile Medical Gas Flow Analyzer prove that the largest percentage error is 2.4%, with the blowing rate on the Peak Flow Meter is 64.0 lpm and the blowing rate on VT mobile is 62.50 lpm, so this tool can be said to be very certain to detect asthma. Then it can be concluded that the peak flow meter is feasible and meets the specified requirements.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.