Tungstic acid surfaces chemisorb NH, and HNOa. Coilectlon of these gases is posslbie by sampling with a hollow tube, the interior of which is coated wlth tungstic acid. Under conditions of laminar flow, the gases diffuse to the wail and are chemisorbed while particles are carried through the tube. Particles are collected with an in-line tube packed with tungstic acid coated sand. Thermal desorption followed by a simple separation and detection by a chemiluminescent NO, analyzer permits analyses at the parts per bllllon and lower concentration range for gaseous and particulate forms of the analytes. Detection limits are 1-3 nglsampie. The precision of analyses of ambient air samples is in the 5-10% relative standard deviation range. Coated hollow tubes conform sufficiently to the mathematical model of tube gas dynamics so as to permit reasonable determination of gaseous diffusion coefficients at ambient concentrations.Ammonia, nitric acid, and sulfuric acid aerosol are important factors influencing the acidity of air and acidity of rain. Ammonium nitrate and ammonium sulfate are solid compounds resulting from atmospheric acid-base reactions of the three acid rain components. Thus, both gaseous and particulate forms of ammonia and nitric acid are expected to be present in air.The determination of gaseous ammonia and nitric acid at the trace concentrations (0.1-5.0 pg/m3) present in comparatively nonpolluted, ambient air as well as discrimination of gaseous from particulate forms is a difficult task. A number of workers have noted particle to gas or gas to particle conversion reactions on filters used to separate particles from the gas phase. A discussion of this aspect of previous work is given in our companion article (I).Analytical procedures for gaseous ammonia have involved absorption on an oxalic acid treated surface as in the ring oven technique of Shendrikar and Lodge (2) modified by Cattell and DuCross (3). Gillett and Ayers (4) report the detection limit of this method to be near 0.05 pg/sample in routine use. Ferm (5) has used an oxalic acid coated diffusion tube to collect NH3 later determined by ion-selective electrode. McClenny and Bennett (6) have reported a method for gaseous ammonia based upon absorption on Teflon beads after filtration to remove particulate ammonia. Collected gaseous ammonia was desorbed by heating and detected by using a photoacoustic detector. The detection limit was approximately 5 ng/sample.Gaseous nitric acid has been collected on sodium chloride impregnated filters after removal of particles by a nontreated prefilter (7,8). Total gaseous and particulate nitrates can be collected on filter combinations such as, for example, a quartz fiber filter and a nylon filter (9). Shaw et al. (IO) developed a method for nitric acid in air employing two parallel sampling lines, one of which includes a diffusion denuder tube to eliminate "OB.Both total and particulate HN03 are determined and the difference is gaseousThe work reported here started with a preliminary study of new approaches t...
First, we briefly review the atmospheric chemistry and previous intercomparison measurements for HCHO, with special reference to the diffusion scrubber Hantzsch reaction based fluorescence instrument used in the field studies reported herein. Then we discuss summertime HCHO levels in five major U.S. cities measured over 1999-2002, primarily from ground-based measurements. Land-sea breeze circulations play a major role in observed concentrations in coastal cities. Very high HCHO peak mixing ratios were observed in Houston (>47 ppb) where the overall median mixing ratio was 3.3 ppb; the corresponding values in Atlanta were approximately >18 and 7.9 ppb, respectively. The peak and median mixing ratios (9.3 and 2.3 ppb) were the lowest for Tampa, where the land-sea breeze also played an important role. In several cities, replicate HCHO measurements were made by direct spectroscopic instruments; the instruments were located kilometers from each other and addressed very different heights (e.g., 106 vs 10 m). Even under these conditions, there was remarkable qualitative and often quantitative agreement between the different instruments, when they were all sampling the same air mass within a short period of each other. Local chemistry dominates how HCHO is formed and dissipated. The high concentrations in Houston resulted from emissions near the ship channel; the same formaldehyde plume was measured at two sites and clearly ranged over tens of kilometers. Local micrometeorology is another factor. HCHO patterns measured at a high-rise site in downtown Nashville were very much in synchrony with other ground sites 12 km away until July 4 celebrations whence HCHO concentrations at the downtown site remained elevated for several days and nights. The formation and dissipation of HCHO in the different cities are discussed in terms of other concurrently measured species and meteorological vectors. The vertical profiles of HCHO in and around Tampa under several different atmospheric conditions are presented. The extensive data set represented in this paper underscores that urban HCHO measurements can now be made easily; the agreement between disparate instruments (that are independently calibrated or rely on the absolute absorption cross section) further indicates that such measurements can be done reliably and accurately for this very important atmospheric species. The data set presented here can be used as a benchmark for future measurements if the use of formaldehyde precursors such as methanol or methyl tert-butyl ether (MTBE) as oxygenated fuel additives increases in the future.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.