The HU-based CTVI method can improve voxel-wise correlations with Galligas PET compared to DIR-based methods and may be a useful approximation for voxels with HU values in the range (-1000, - 600). With further clinical verification, HU-based CTVI could provide a straightforward and reproducible means to estimate lung ventilation using free-breathing 4DCT.
Counter WB, Wang IQ, Farncombe TH, Labiris NR. Airway and pulmonary vascular measurements using contrast-enhanced micro-CT in rodents. Am J Physiol Lung Cell Mol Physiol 304: L831-L843, 2013. First published April 5, 2013 doi:10.1152/ajplung.00281.2012.-Preclinical imaging allows pulmonary researchers to study lung disease and pulmonary drug delivery noninvasively and longitudinally in small animals. However, anatomically localizing a pathology or drug deposition to a particular lung region is not easily done. Thus, a detailed knowledge of the anatomical structure of small animal lungs is necessary for understanding disease progression and in addition would facilitate the analysis of the imaging data, mapping drug deposition and relating function to structure. In this study, contrast-enhanced micro-computed tomography (CT) of the lung produced high-resolution images that allowed for the characterization of the rodent airway and pulmonary vasculature. Contrast-enhanced micro-CT was used to visualize the airways and pulmonary vasculature in Sprague-Dawley rats (200 -225 g) and BALB/c mice (20 -25 g) postmortem. Segmented volumes from these images were processed to yield automated measurements of the airways and pulmonary vasculature. The diameters, lengths, and branching angles of the airway, arterial, and venous trees were measured and analyzed as a function of generation number and vessel diameter to establish rules that could be applied at all levels of tree hierarchy. In the rat, airway, arterial, and venous tress were measured down to the 20th, 16th, and 14th generation, respectively. In the mouse, airway, arterial, and venous trees were measured down to the 16th, 8th, and 7th generation, respectively. This structural information, catalogued in a rodent database, will increase our understanding of lung structure and will aid in future studies of the relationship between structure and function in animal models of disease. computed tomography; contrast agents; pulmonary circulation; airway nomenclature THE LUNG IS A COMPLEX ORGAN that works dynamically and must react to changes in posture, environment, and disease (20). Its major function is gas exchange, bringing oxygen into the body while removing carbon dioxide. To accomplish this task, a well-coordinated interaction between the lung and pulmonary circulation is essential. The rodent lung is comprised of two branching networks: the airways and pulmonary vasculature. With the advent of small animal imaging systems, researchers are able to visualize these networks in situ and noninvasively study the progression of lung disease and assess drug efficacy in animal models of disease. Much of this research involves combining the anatomical data obtained using computed tomography (CT) with the functional data obtained using single photon emission computed tomography (SPECT) or positron emission tomography (PET). A detailed knowledge of the structure of the lung would facilitate the mapping of functional data relative to lung anatomy and thus further our understandi...
Chronic obstructive pulmonary disease is a leading cause of morbidity and mortality worldwide. Exposure to cigarette smoke (CS) is a major risk factor for developing this chronic airflow impairment, but the early progression of disease is not well defined or understood. Ventilation/perfusion (V/Q) SPECT provides a noninvasive assessment of lung function to further our current understanding of how CS affects the lung. Methods: BALB/c mice were imaged with V/Q SPECT and CT after 8 and 24 wk of whole-body exposure to mainstream CS. Bronchoalveolar lavage was collected and cell differentials produced to determine inflammatory patterns. Histologic lung sections were collected, and a semiautomated quantitative analysis of airspace enlargement was applied to whole histology slices. Results: Exposure to CS induced an inflammatory response that included increases in the numbers of both mononuclear cells and neutrophils. Airspace enlargement was also significantly increased at 8 wk of CS exposure and was still more pronounced at 24 wk. Ventilation and perfusion correlation at the voxel level depicted a significant decrease in matching at 8 wk of CS exposure that was also apparent after 24 wk. The standard deviation (SD) of the log(V/Q) curve, a basic measure of heterogeneity, was increased from 0.44 6 0.02 in age-matched controls to 0.62 6 0.05 with CS exposure at 24 wk, indicating an increase in V/Q mismatching between 8 and 24 wk of CS exposure. CT, however, was not capable of discriminating control from CS-exposed animals at either time point, even with greater resolution and respiratory gating. Conclusion: This study demonstrated that, before CT detection of structural changes, V/Q imaging detected changes in gas-exchange potential. This functional impairment corresponded to increased lung inflammation and increased airspace enlargement. In vivo V/Q imaging can detect early changes to the lung caused by CS exposure and thus provides a noninvasive method of longitudinally studying lung dysfunction in preclinical models. In the future, these measures could be applied clinically to study and diagnose the early stages of chronic obstructive pulmonary disease.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.